HX-20/RS-232 Device Protocol
Protocol Format: BLPSC

B:

Baud Rate

0110
1150
2300
3600
41200
52400
6 (default)4800

L:

Word Length

77-bit word
8 (default)8-bit word

P:

Parity

N (default)None
EEven
OOdd

S:

Stop Bits

11 stop bit
2 (default)2 stop bits

C = Active Control Lines

Value

CTS

DSR

RTS

CD

0normalnormallow levelnormal
1normalnormallow levelignore
2normalnormalhigh levelnormal
3normalnormalhigh levelignore
4normalignorelow levelnormal
5normalignorelow levelignore
6normalignorehigh levelnormal
7normalignorehigh levelignore
8ignorenormallow levelnormal
9ignorenormallow levelignore
Aignorenormalhigh levelnormal
B (default)ignorenormalhigh levelignore
Cignoreignorelow levelnormal
Dignoreignorelow levelignore
Eignoreignorehigh levelnormal
Fignoreignorehigh levelignore


HX-20 Default Protocol
for RS-232 Port

Data Rate:4800 Baud.
Word length:8 bits.
Parity:None.
Stop bits:2.
CD (Carrier Detect):Ignored.
RTS (Ready to Send):Held "high" by HX-20.
Controlled by external
device. "High" means
HX-20 may transmit data;
"low" causes HX-20 to
wait.
DSR (Data Set Ready):Normal.
CTS (Clear to Send):Ignored.