ASTM B 117 :
Standard Practice for Operating Salt Spray (Fog)
Apparatus |
|
This practice describes the apparatus, procedure, and
conditions required to create and maintain the salt spray
(fog) test environment. Suitable apparatus wich may be
used is described in Appendix X1. This practice does not
prescribe the type of test specimen or exposure periods
to be used for a specific product, nor the interpretation
to be given to the results.
The values stated
in SI units are to be regarded as standard. The
inch-pound units in parentheses are provided for
information and may be approximate.
Use a 5% salt solution at 92-97 degrees F in a sealed
weather cabinet. Scribe X in steel zinc phosphated
test panel to bare metal. Inspect every 24
hours. End test and total hours after 1/4"
creepage from scribed area. Creepage shall not
exceed 1/4" in either direction from scribe line
after 500 hours exposure.
|