Super 400 UPS in 10&20 KVA
Simi Electronics
please contact
Simi Electronics, Ngpur
Simi Electronics
   Prices at Nagpur exlussive of taxes

10 KVA Rs.311000.00  Suitable for 50 computers with colour VDU
20  KVA Rs.481000.00   For 100  computers
[email protected]
 
Salient Features of S400  model on line UPS systems

1.
True On-line double conversion Technology, The Best Available technology  for
    guarding missioncritical systems.Duel Microprocessor based System. Uses IGBTs
    as basic power devices. Rugged and   Robust design to provide fit and forget
    reliability. Power factor correction, even with low power factor load,to >0.9 resulting
    lower power consumption.

2.
wide input voltage range (+25%, -30%). This UPS is designed to work on 3Phase power
( as 10 KVA load should not be connected to a single phase) and it can work under wide input
   voltage range . The input voltage range is 290V to 518V Phase to phase Voltage.

3.. Battery Management, temperature compensated charging.

4. .This UPS supplies
Precise Sine Wave power thus providing  protection from  all type of disturbances
    including Lightning and surges, Voltage sags,  Harmonics and power Outages. With capability to
    cater 100% non Linear load
suitable for any kind of load.

5.
1+1 redundant configuration possible with one more UPS for 100% availability . 2 or 3 UPSs can be
    configured to work on  common battery bank .DG can also be connected to this UPS  as an
    additional back up source in this configuration . Supper 400 UPS is having cross redundancy.
    That is the charger of one UPS  can be used with the inverter of the other UPS.

6. This UPS is designed to work on 3Phase power( as 10 KVA load should not be connected to a single
    phase) and it can work under wide input voltage range . The
input voltage range is 290V to 518V
    Phase to phase Voltage.

7. Suitable for
many hours of back up time using any type of batteries. Different batteries require
    chargers of different specifications. While Lead acid (Tubular and automotive ) batteries require float
    boost charging  SMF batteries need constant voltage - constant current chargers . If it is Ni-Cd
    batteries then it needs float boost charging at a different level. All these can be set  in the UPS . The  
    charger also provides temperature compensated  charging of batteries to  protect the batteries.


8.
Fault Tolerance. The fail-safe static bypass ensure the power supply to your critical load even
   during UPS over load or fault conditions. In case of a fault the load is transferred to the stand by
   (by pass) Power,

9.
The servicing of the UPS can be done , components can be repaired/replaced and restart the systems
    and transfer the load to UPS  , all  are possible
with out disturbing the load. Access to the inside
    components of the UPS is possible from the front side only and hence the space required for
     installation is also less compared to other UPS systems.

10.To ensure safe working of the critical load  this  UPS do a
self test including battery every time
     it is switched on. 

11.
LCD Display l on the front panel. The user can read the status of the UPS with readings of all
    parameters including voltages current of input/output,Battery,  load , back up time, battery charge
    etc.from the LCD panel .

12.
Data logging and event history. Supper 400 can identify and display 45 fault conditions on its front
     panel.   Also It can store and display 200 alarm events  (input over voltage,  power failure, power
     restoration ,ups on ,off etc.). the customer can find out if there was a power failure  last week on
     one particular day  and  what time it happened and what was the load at that time and What was
     the out put voltage.

13.I
ntelligent network interface port. UPS monitoring is possible  with site Net   software. All major OS
    platforms are supported including windows, UNIX, Novel, HP, DEC,   and many others.

14.
Cold start facility with 100% load  in the absence of utility power.

15.
Smallest foot print This Equipment is constructed zinc-plated steel structure  an the front panel is
      held in place   by a snap fit arrangement.  Size (WxDxH) 450x650x1150 (mm)


16 .
Excellent service backup as we are specialist in UPS System having  12 years of experience in
      UPS maintenance and we extend our maintenance support to all major organizations in
      Vidharbha . We  are having  Liebert(Emerson)  trained engineers  for Liebert UPS Systems.These are in
      addition to the support from Liebert (Emerson) who is having country wide service network with 
      India'sbest available manpower.



     All these are in addition to the normal specifications  of a standard UPS system

   For further details  visit 
www.liebert.com