Paramètres related to :

CRT/MDI and EDIT

 

Symbol

Param

Bit

Description

 

DCS

0001

2

1= Cycle start by start key on MDI panel.

EBCL

0010

1

1= EOB code by « * »;   0= EOB code by « ; ».

INHM

0013

4

1= Menu programming inefective;  0= Menu programming effective.

CBLNK

0015

0

1= Cursor blinks;  0= Cursor doesn’t blink.

CPRD

0015

7

1= Set to mm or inch if dec. Point is omitted  0= Least inp. Incr.

NPRD

0016

3

1= Inp. And display without dec. Point,;  0= With dec. Point.

OPG7

0017

6

1= Feed hold actuated with soft. Operator’s panel.

OPG6

0017

5

1= Protect key actuated with soft. Operator’s panel.

OPG5

0017

4

1= Opt-blk-skip, Sing-blk, Mach-lock, D-run. Actuated soft Panel.

OPG4

0017

3

1= Jog-fdrate, Overr, Raptrvse Overr. Actuated soft. Panel.

OPG3

0017

2

1= Axis select, Man. Puls Generator. Actuated soft Panel.

OPG2

0017

1

1= Jogfd axis select, Jograptravers. Actuated soft Panel.

OPG1

0017

0

1= Mode Select Actuated with soft Operator’s Panel.

EDITB

0018

7

1= Edit B is effective;   0= Edit is standard.

DSPN

0023

6

1= The CRT screen is displayed in Spanish.

DHNG

0023

5

1= The CRT screen is displayed in Hangeul.

DITA

0023

4

1= The CRT screen is displayed in Italian.

DCHI

0023

3

1= The CRT screen is displayed in Chinese.

DFRN

0023

2

1= The CRT screen is displayed in French.

DGRM

0023

1

1= The CRT screen is displayed in German.

DJPN

0023

0

1= The CRT screen is displayed in Japanese.

MMDL

0028

3

1= Modal status is displayed in MDI operation B.

DACTF

0028

2

1= Act. Speed is display on current position and prgm Check..

PRCMSG

0028

1

Display on Prgrm Check Screen  1= PMC-MES.   0= Rem. Motion.

PRCPOS

0028

0

Display on prgrm Check Screen  1= Abs. Coor.   0= Rel. Coor.

NDSP4

0035

3

1= The current position of 4th axis is not displayed.

NDSPZ

0035

2

1= The current position of Z axis is not displayed.

NDSPY

0035

1

1= The current position of Y axis is not displayed.

NDSPX

0035

0

1= The current position of X axis is not displayed.

FLKY

0038

3

1= CRT/MDI Keyboard uses a full key.

SORT

0040

4

Prgrm-Library is displayed in : 1= Num. Order   0= Norm. Order.

NAMPR

0040

0

1= Displays prgrm Name on the directory Display.

CLER

0045

6

RST. PB. Selects :  1= Clear    0= Reset Conditions

MBCLR

0057

7

1= MDI-B Prgrm is cleared by the reset operation.

IGNCOL

0060

7

9’’ High-Resolution Display  1= Color,   0= Monochrome.

C14DGN

0060

3

Diagnose Screen  1= 14’’,   0= 9’’

ALL78

0061

7

1= 7th & 8th axse Display in common position Display.

DSP78

0061

6

1= 7th & 8th Axes display in Abs. & Rel. Position Coord.

MTDSPI

0063

0

1= Machine coor. Sys. Displ. To meet the input systeme.

NPA

0064

5

1= Screen is not switched to the Alarm/Message Page

SETREL

0064

0

1= Preset is made for each axis in Rel. Pos. Display.

UPKY

0130

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

DWNKY

0131

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

RGTKY

0132

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

LFTKY

0133

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

FWDKY

0134

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

BACKY

0135

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

RTDKY

0136

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

LTYLY

0137

 

Set Jogfeed axes & Dir. On Software Operator’s Panel.

NSW11

0140

 

Set the names of Genral Purpose Switches on Software Ope. Panel.

NSW88

0203

 

Set the names of Genral Purpose Switches on Software Ope. Panel.

 

 

 

 

 