......................................................................................................Home
1-Range of Regulated DC Power Supply with dual output, suitable for research laboratories and educational establishments:-
Inout- 240 VAC / 50 to 60 Hz
Outputs- 12 VDC / 24 VDC.
................300 VA / 600VA -------
............................................................Maximum required VA to be advised by customer.
----------------------------------------------------------------------------------------------
2-Our Capacitive Discharge Welder, suitable for foundaries and research laboratories where thermocouple connections are required to be made .
Input- 240 VAC
Output- Maximum available energy 140 Joules (Watt-Seconds).
Adjustable power output with visual indication of charging process. Stored energy can either be selected at three settings, 52 W-Sec , 94 W-Sec, 140 W-sec or power storage can be stopped at any values between 0 to 140 W-Sec.
.............................................................Higher energies to be advised by customer.
---------------------------------------------------------------------------------------------
3-Our Analogue Surfce Crack Detector, suitable for scanning small surface area.
This instrument can be used in place of dye penetrant or magnetic particle inspection
without involving any surface contamination.
Input:- 240VAC / 50 to 60 Hz
Output- Crack detection is shown by audible and visual indication
-----------------------------------------------------------------------------------------------
4-Our Analogue Eddy Current (TI-1) instrument can be used for corrosion
detection, surface and sub-surface crack detection.
Input:- 240VAC / 50 to 60 Hz
Output- Crack detection is shown by audible and visual indication.
----------------------------------------------------------------------------------------------
We have recently working on a new Analogue Eddy Current ( TI-2 ) instrument.
This versatile instrument has four outputputs to the probe :-
1- normal AC of differnt frequencies, selectable by the nobe.
2- AC & DC output to the probe.
3- Modulated AC (the carrier wave is made to chirp; the carrier pulsates at high frequency and high amplitude.
4- an auxiliary square wave output.
This instrument will shortly replaces TI-1 model.
---------------------------------------------------------------------------------------------
We have just started a second project, the research and development of a new
design of Pressure and Temperature Gauge (U-1) aimed at the petrochemical
industry. This gauge, which would be strapped to the outside of the pipes, can
also be modified to be used for condition monitoring (U-2) of pressure vessels.
We also supply:-
1-Marine components and accessories
1.1- Marine Shock Pads
Type A |
Typical Application |
Energy (tonne per meter) |
---|---|---|
1-Sliding (R) |
Oil Services Terminal |
1.12 up to 21.8 |
2-Buckling |
Barge Jetty |
0.41 up to 56 |
3-Shear |
Harbour |
0.147 up to 4.350 Shock load 60 KN |
4-Spring |
Accidental overload energy absorbing device. (can be placed in series with elastic fenders to prevent overload damage to the ship, berth and fender.) |
|
Type B |
Typical Application |
Lenth cm |
Width cm |
---|---|---|---|
1- Cylinder |
To protect the boat from damage during mooring |
14 - 190 |
15 - 81 |
2-Pear |
To protect the boat from damage during mooring |
29 - 118 |
23 - 86 |
3- fender |
fitted along side of a boat |
|
|
2 - Lifting Accessories ( chain and shacklles)
We no longer supply these items.
Please refer to:-
Zhangjiakou Coal Mining Machinary Co. http://www.zmj.cn
subsidiary of :-
China National Coal Group Corporation http://www.chinacoal.com
3- Protective Coatings
A range of high temperature protective coatings used in processing
equipment such as LNG plants.
The coatings have sufficient flexibility to operate at constant or cyclic
temperatures up to 400°-500° C.
4- Tanks and Pressure Vessel
5- Material Testing Equipment
Non-destructive testing ( NDT ) and destructive testing equipment.
----------------------------------------------------------------------------------Up
...........................................................................................................