Physical Properties of LTR 720

Tensile

45,000 psi

Elongation

10% in 2 inches

Impact

43 ft. lbs. (Charpy)

Shear

31,000 psi

Working Temperature

717° F to 728° F

Corrosion Penetration

less than 300 x 10-6

Thermal Expansion

15.2 x 10.6 in. / F

Specific Gravity

6.6

Electrical Conduction

26% of copper std.

Rockwell Hardness

60

 

STEP 1 CLEANING: Work surfaces must be prepared by removing oxidation. Oxidation will prevent penetration of the rod into the work surface. Cleaning can be accomplished by using a wire brush, sanding or scraping to remove oxidation, dirt and foreign material.

STEP 2 HEATING: Heat the work surface to be repaired using appropriate torch. Most repairs can be made using a propane torch. Do not heat the rod, only the work surface, until surface is hot enough to flow the rod.

STEP 3 REPAIRING: Apply rod to the work surface with a scrubbing motion. Build up and excess of rod around the break, using the rod to draw the molten material over the hole or crack. Allow to cool naturally.