|
|
|
| CAUTION: Parts on this page are for a variety of servers. These parts may or may NOT work with a specific server and need to be verified in EDB or in the actual Options or Spare Parts Pages. | |
|
|
|
| Description | Spare Part Number |
|---|---|
SCSI Hard Drives and Cables
Server's Removable Media Bays. 14
|
|
| Internal 2-drive SCSI Hot-plug Drive Cage | 253761-001 |
| SCSI Disk Drives | |
| Wide Ultra3 SCSI Universal Disk Drives | |
| 18.2GB Hot Plug, 10K, 1" | 152190-001 |
| 9.1GB Hot Plug, 10K, 1" | 152188-001 |
| Wide Ultra3 SCSI Disk Drives | |
| 36.4GB, Non Hot Plug, 10K, 1.6" | 152193-001 |
| 18.2 GB, Non Hot Plug, 10K, 1.0" | 152191-001 |
| 9.1GB, Non Hot Plug, 10K, 1.0" | 152189-001 |
| Wide Ultra2 SCSI Disk Drives 20 | |
| 18.2GB Hot Plug, Wide Ultra2 SCSI, 7,200RPM, 1.0" | 104663-001 |
| 18.2GB Non Hot Plug, Wide Ultra2 SCSI, 10,000RPM, 1.6" | 386540-001 |
| 9.1GB Hot Plug Wide Ultra2 SCSI, 10,000RPM, 1.0" | 386536-001 |
| 9.1GB Non Hot Plug Wide Ultra2 SCSI, 10,000RPM, 1.0" | 386539-001 |
| 9.1GB Hot Plug Wide Ultra2 SCSI, 7000RPM, 1.0" | 349531-001 |
| 9.1GB Non Hot Plug Wide Ultra2 SCSI, 7000RPM, 1.0" | 349534-001 |
| 4.3GB Hot Plug Wide Ultra2 SCSI, 10,000RPM, 1.0" | 386535-001 |
| 4.3GB Non Hot Plug Wide Ultra2 SCSI, 10,000RPM, 1.0" | 386538-001 |
| 4.3GB Hot Plug Wide Ultra2 SCSI, 7,000RPM, 1.0" | 349530-001 |
| 4.3GB Non Hot Plug Wide Ultra2 SCSI, 7,000RPM, 1.0" | 349533-001 |
| (Wide-Ultra SCSI-3 Hard Drive Specs) | |
| 36.4GB Hot Plug, Wide Ultra SCSI-3, 7200RPM, 1.6" | 104659-001 |
| 18.2GB Wide Ultra SCSI-3 Hot Plug Low Profile 7200RPM Hard Drive | 104660-001 |
| 18.2 GB Hot Pluggable, Wide-Ultra SCSI-3, 1,6", 10,000 RPM | 336382-001 |
| 18.2 GB Hot Pluggable, Wide-Ultra SCSI-3, 1.6", 7200 RPM | 313764-001 |
| 9.1 GB (Non-Hot Pluggable only), Wide-Ultra SCSI-3 Hard Drive, 1" (See SA 2087B) | 339515-001 |
| 9.1GB (Non-Hot Plug), Wide-Ultra SCSI-3 Hard Drive, 1.6" | 199886-001 |
| 9.1 GB Hot Pluggable, Wide-Ultra SCSI-3, 10,000
RPM, 1.6" 9 10
(1st Generation 9.1GB, Hot Plug, 10K, 1.6") |
304866-001 |
| 9.1 GB Hot Pluggable, Wide-Ultra SCSI-3, 10,000
RPM, 1.0" 9 10
(2st Generation 9.1GB, Hot Plug, 10K, 1.6") |
336381-001 |
| 9.1 GB Hot Pluggable, Wide-Ultra SCSI-3, 1.0", 7200RPM, (SCA-80) | 313715-001 |
| 9.1GB Hot Pluggable, Wide SCSI, 1.6" | 199888-001 |
| 9.1 GB (Non-Hot Plug), Fast SCSI-2, 1.6" | 199885-001 |
| 4.3 GB Hot Pluggable, Wide Ultra, 10,000RPM, 1.0" 9 | 304860-001 |
| 4.3 GB Non Hot Plug, Wide Ultra, 10,000RPM, SCSI-3, 1.0" 9 | 304861-001 |
| 4.3 GB (Non-Hot Pluggable only), Wide-Ultra, SCSI-3, 1.0" (See SA 2087B) | 339514-001 |
| 4.3 GB Hot Pluggable, Wide Ultra SCSI-3, 1.0" | 242622-001 |
| 4.3 GB (Non-Hot Plug), Wide Ultra, SCSI-3, 1.0" | 242606-001 |
| 4.3 GB Hot Pluggable, Wide Ultra SCSI-3, 1.0" | 199598-001 |
| 4.3 GB (Non-Hot Plug), Fast-Wide, SCSI-2, 1.0" | 199599-001 |
| 4.3 GB Hot Pluggable Fast SCSI-2 | 199594-001 |
| 4.3 GB (Non-Hot Plug) Fast SCSI-2 | 199585-001 |
| 2.1 GB Hot Pluggable Wide Ultra, 1" | 242603-001 |
| 2.1 GB (Non-Hot Plug) Wide Ultra, 1" | 242604-001 |
| 2.1 GB Hot Pluggable Fast-Wide SCSI-2, 1" | 199878-001 |
| 2.1 GB Hot Pluggable Fast-Wide SCSI-2 | 199643-001 |
| 2.1 GB (Non-Hot Pluggable) Fast-Wide SCSI-2 | 199644-001 |
| 2.1 GB Hot Pluggable Fast SCSI-2 | 199428-001 |
| 2.1 GB (Non-Hot Pluggable) Fast SCSI-2 | 142272-001 |
| 1.05 GB Hot Pluggable Fast SCSI-2 18 | 146717-001 |
| 1.05 GB (Non-Hot Pluggable) Fast SCSI-2 | 146799-001 |
| SCSI Controllers | |
| SMART-2DH Array Controller | 295243-001 |
| SMART-2SL Array Controller | 242777-001 |
| Dual Channel Wide-Ultra SCSI-3 (VHDCI connectors) | 295626-001 |
| Wide-Ultra SCSI-3 Controller | 272514-001 |
| 64-Bit Wide Ultra2 SCSI Dual Channel Controller | 348759-001 |
| Fibre Channel Array Controller | 204069-001 |
| Smart Array Controller (Original) 21 | 142130-001 |
| Smart Array Controller (Original) 21 | 181132-001 |
| SCSI Cables | |
| VHDCI to Wide, 6' | 340651-001 |
| VHDCI to Wide, 12' | 340652-001 |
| VHDCI to Fast/Narrow/Standard (50-Pin), 6' | 340665-001 |
| VHDCI to Fast/Narrow/Standard (50-Pin), 12' | 340666-001 |
| External Wide to Wide SCSI-2 Cable (6') | 189635-002 |
| External Wide to Wide SCSI-2 Cable (12') | 189635-003 |
| External Standard to Wide SCSI-2 Cable (6') | 189636-002 |
| External Standard to Wide SCSI-2 Cable (12') | 189636-003 |
| External Standard to Standard SCSI-2 Cable (12') | 146776-004 |
| Internal Wide to Wide, Point to Point, SCSI-2,
18" and 36" cables |
271937-001 |
| 20" Internal to External Fast-Wide (68-pin) SCSI Cable (Smart-2 Array Controller) | 189639-001 |
| 20" and 34" Shielded Internal to External Fast-Wide
SCSI Cable (Smart-2 Array Controller) for Ultra capable ProLiant Storage
Systems. See EA: EX981106_EW03.
Options p/n of 20": 341107-B21 (ships with /U1, /U2, and
/UE)
|
341110-001 |
| Internal Fast-Wide SCSI-2 Cable w/Termination
(4 Device/300) |
189627-001 |
| Internal Fast-Wide SCSI-2 Cable w/ Termination
(4 Device/500) 2 |
212050-001 |
| Internal Fast SCSI-2 Cable w/Terminator (4 Device/300) 6 | 212052-002 |
| Internal Fast SCSI-2 Cable w/Terminator (4 Device/500) 6 | 212052-001 |
| Internal Fast SCSI-2 Cable w/Terminator (7 Device/500) 6 | 211409-001 |
| 2-Device Internal Cable w/Terminator, Fast, (36") | 148728-001 |
| Internal SCSI Cable, Fast Wide Point to Point (23") | 189637-003 |
| Internal SCSI Cable, Fast Wide Point to Point (32") | 189637-004 |
| Diskette Cable | 143706-001 |
| Internal Fast-Wide SCSI-2, 23", Point to Point | 189637-001 |
| External 100-Pin to two 50-Pin Connectors
(Y Splitter, Smart-1) |
142159-001 |
| External Daisy Chain Cable (DLT, Centronics to Centronics) (3') | 199713-001 |
| External Fast / Standard (50-Pin) to Centronics (6') | 199714-001 |
| External Fast-Wide (68-Pin) to Centronics (6') | 199780-001 |
| SCSI Terminator & cable, 1.5", (68-Pin) (Used w/ PL2500 integrated SCSI controller) | 295947-001 |
| DLT Active Terminator (68-Pin Centronics) | 199715-001 |
| DLT Terminator (50-Pin Centronics) | 306278-001 |
| Hot Pluggable Drive Trays | |
| Hot Pluggable Drive Tray, 1", SCA-80 Wide, 80 Pin | 242801-001 |
| Hot Pluggable Drive Tray, 1", Fast-Wide, 68-Pin | 199880-001 |
| Hot Pluggable Drive Tray, 1", Fast, 50-Pin | 242593-001 |
| Hot Pluggable Drive Tray, 1.6", SCSI-2, Fast, 50-Pin (Standard) | 146781-001 |
| Hot Pluggable Drive Tray, 1.6", SCSI-2 Fast-Wide, 68-Pin | 199656-001 |
| Wide Ultra2 SCSI Blanking Tray | 122759-001 |
| SCSI Adapters | |
| 50 Pin to 68 Pin (Standard to Wide) 4 | 189638-001 |
| 68 Pin to 50 Pin (Wide to Standard) 5 | 189631-001 |
| 50 Pin to 68 Pin (Standard to Wide) Flex Adapter
(Cable adapter required to be used with the 10/20 DLT Tape Drive in the PL1850R) See: EA EL981113 EW01 |
386879-001 |
| Jumpers, SCSI ID QTY = 50 (for setting the SCSI ID of Non Hot Plug disk drives) | 121775-001 |
| MISC Cables | |
| ProLiant 6000 & 7000 Pentium Pro
Thermistor / Removable Media Bay Interlock Cable Assemblies |
211443-001 |
| ProLiant 6000 & 7000 Pentium II Xeon Thermistor Cable Assembly | 312263-001 |
| 2' Power cord C13 to NEMA 5-15 power cord (Standard US plug type) | 187335-001 |
| Additional information on World Wide power cords is available in the UPS Power Plug & Receptacle Types page | |
| Tape Drives | |
| 525 MB ACA Tape Drive | 142073-001 |
| 1.2 GB Tape Drive | 199615-001 |
| 2/8 GB DAT Tape Drive (Clam Gray) 1112 | 142074-001 |
| 2/8 GB DAT Tape Drive (Beach Gray) 1112 | 142074-201 |
| 4/8 GB DAT Tape Drive | 295163-001 |
| 4/8 GB SLR Tape Drive | 340591-001 |
| 4/16 GB TurboDAT Tape Drive (Clam Gray) 1113 | 199464-001 |
| 4/16 GB TurboDAT Tape Drive (Beach Gray) 1113 | 199464-201 |
| 4/16 GB TurboDAT Autoloader
Internal Tape Drive (Clam Gray) 11 13 |
199466-001 |
| 4/16 GB TurboDAT Autoloader
Internal Tape Drive (Beach Gray) 1113 |
199466-201 |
| 12/24 GB DAT Tape Drive (DDS-3) | 340593-001 |
| 10/20 Internal DLT 13 | 199746-001 |
| 10/20 Table Top DLT | 199676-001 |
| 15/30 Internal DLT 13 | 242468-001 |
| 15/30 Table Top DLT | 242469-001 |
| 35/70 GB Internal Tape Drive 313 | 242853-B21 |
| 35/70 GB DLT Table Top Tape Drive | 242854-B21 |
| Tape Drive Terminators | |
| Terminator Assy: 20/40 DLT Tape Drive, External, (Table Top), 50-Pin | 171258-001 |
| Terminator Assy: 35/70 DLT Tape Drive, External, 68-Pin | 171259-001 |
| Miscellaneous Disk and Tape Drive Spares | |
| DAT / SLR Adapter kit, female SCSI, 50 to 68 Pin | 189638-001 |
| DAT / SLR Rails Kit, 3.5" | 162200-001 |
| 3.5" to 5.25" Bracket (Removable Media Bay) 14 | 243231-001 |
| Swizzle Sticks(Green) (Pair) 15 | 143856-001 |
| 1.44 MB Diskette Drive (ProLiant 3000 and 5500) 19 | 144207-201 |
| Wide Ultra2 SCSI Blanking Tray | 122759-001 |
| 6-Cartridge Magazine, DAT | 154262-001 |
| 8-Cartridge Magazine, DAT | 154262-002 |
| Miscellaneous Tower and Rack Spare Part Numbers | |
|---|---|
| Tower, Key Lock Assembly 7 | 148725-001 |
| Rack, Handle / Key Lock Assembly 7 | 165798-001 |
| 5.25" Hard Drive Mounting Bracket 8 | 243231-001 |
| 24 Inch Slide Rails (Qty=1 Pair)
(Installed on CPU Chassis) 7 |
165689-003 |
| 22 Inch Slide Rails (Qty= 1 Pair) (Installed on Option's Chassis) 7 | 165689-002 |
| Mounting Brackets (22" & 24") (Installed on Rack Chassis) | 187374-001 |
| 26" Slide Rails (PL6000, PL6500, PL7000) | 296377-001 |
| Slide Rails for the 1U Switch Box | 298845-001 |
| Hot Pluggable Fast-Wide Disk Drive Backplane (5 bays) 7 | 169185-001 |
| Hot Pluggable Fast (50 Pin) Disk Drive Backplane 7 | 190060-001 |
| SCSI Pass Thru 7 (Fast-Wide, 68 Pin) | 199612-001 |
| SCSI Pass Thru 7 (Fast, 50 Pin) | 142266-001 |
| Power Switch & LED Bracket 7 | 165688-001 |
| Cable Management Arm 7 | 187367-001 |
| Cable Management Arm Bracket 7 | 187396-001 |
| Fan 7 | 165682-001 |
| Captive (cage) Nuts (QTY=50) 7 | 169917-001 |
| Fixing Screws (Quantity=100) 7 | 165799-001 |
| Front Chassis Handles (QTY=2, five screws and one torx bit) 7 | 165690-001 |
| Coupling Kit (42U only) | 169918-001 |
| Stabilizing Feet (42U only) | 189907-001 |
| Rack Sidewall Kit (42U only) | 165652-001 |
| Drawer (2U) | 303607-B21 |
| Fan Kit, High Altitude, PL2500 only | 327901-001 |
| Depth Adjustable Fixed Rail Kit (DAFRK) 16 | 332578-001 |
| Sliding Shelf Kit (SSK) 16 | 332579-001 |
| Grommet, 36U Rack
(See Service Advisory EX980707-SW02: Chafing of Power Cables) |
329178-001 |
| Jumpers, Fan, QTY=5 (used when configuring between some Tower/Rack configurations) | 165691-001 |
| Misc | |
| Ethernet Loopback Plug | 317465-001 |
| Ribbon Cable, Remote Insight Lights Out Edition | 195724-001 |
| Ribbon Cable, Remote Insight Lights OutEdition (required for the ProLiant 8500 and RILO in order to set up the Virtual Power Button. | 195254-B21 |
| Note 2: Use this
Fast-Wide (68-Pin) multi-device cable in servers like the PL2500 for interfacing
tape drives and Non Hot Plug disk drives in the Removable Media Bays. For
Fast devices, the SCSI Adapter (50 Pin to 68 Pin), Option's part number
212055-00, must be used in this configuration.
Note 3: Can not be installed in either the Tower or Rack Mount SCSI Storage Expander because of internal SCSI cabling and physical incompatibilities. Note 4: In servers beginning with the ProLiant 2500, this adapter can be installed directly to a Fast device to allow interfacing it to a Fast-Wide controller. In servers previous to the ProLiant 2500, SCSI adapters can only be installed between the SCSI Controller and the SCSI cable and not directly to the SCSI device. Note 5: Use this adapter installed directly to the Fast-Wide connector on the Smart-2 Array Controller to allow interfacing to Fast devices using a Fast multi-device SCSI cable. Compaq's 32-Bit Ultra-Wide controllers come equipped with both Fast-Wide and Fast connectors. Note 6: When interfacing these cables to the Smart-2 controller, the 68 Pin to 50 Pin Adapter, Option P/N: 189630-001, must be used. Note 7: These parts do not have Option's part numbers assigned to them and must be ordered using their spare part numbers. Note 8: This hard drive mounting bracket is used to mount a 3.5" hard drive which will allow it be installed into the Server's Removable Media Bays. Note 9: Room temperature must not exceed 86 degrees Fahrenheit (30 degrees C) for all 10,000 RPM hard disk drives, rack or tower. Note 10: 9.1 GB / 10,000 RPM hard drive in a rack configuration require an Optional Redundant Power Supply fan unit for adequate cooling. Note 11: Clam Gray is a darker shade than the Beach Gray and is referring to the color of the tape drive's front bezel. Beach Gray is the color of the Server's and SCSI Storage Expander's outer panels and is a much lighter gray. Be sure to differentiate between the two colors when ordering a replacement. See Service Advisory 1013. Note 12: This is a half-height device. Note 13: This is a full-height device. Note 14: Removable Media Bays are 5.25" wide. Non Hot Plug SCSI disk drives are 3.5". Use either the Green Swizzle sticks or the 3.5" to 5.25" Removable Media Bay brackets. Their part numbers are listed above in the Miscellaneous Disk and Tape hardware . Refer to the Server's documentation to determine which is required. Note 15: Swizzle sticks come standard when ordering Non Hot Plug disk drives. Note 16: These are sheet metal rack accessories for installing Compaq servers and peripherals in Compaq and most 3rd party server racks. The DAFRK is used to mount Compaq rack-mountable servers. The SSK is used with the Compaq ProLiant 850R, Microcom6000, drive arrays, and other devices. The Options part number for the DAFRK is: 332558-B21. The Option's part number for the SSK is: 332564-B21. See Service Advisory 2028 for additional details. The SSK shelf supports 110lbs and includes a Cable Management Arm. Note 18 This particular disk drive is not supported in the ProLiant 3000 and ProLiant 5500 because of physical incompatibilities. Note 19 The spare part number for the 1.44MB Diskette Drive for the ProLiant 3000 and ProLiant 5500 listed in the QRG, 144207-001, will not properly connect to the diskette cable that comes standard with these servers.. Instead, use part number 144207-201 when ordering a replacement diskette drive. Note 20 SCA 80 Wide Ultra2 SCSI disk drives are supported in only hot plug Wide Ultra2 SCSI drive trays from Compaq. Non hot plug SCA 80 drives are not supported in any configuration at this time. Because of issues involved with combining power, control, and data conductors on one connector, multi-device SCA 80 SCSI cables are not available. See Service Advisory 1277 for further details. Note 21 The firmware for the original Smart Array Controller is no longer being upgraded. Use Options Rompaq SP8050, Version 2.47B to upgrade this controller to its latest firmware version, V2.26. Two spare part numbers were generated for this controller. It is advisable to replace hardware with the same spare part number of the part being replaced. This Smart Array Controller was available in only an EISA version. |
|