SPECIFICATIONS:

Formatted: .................... 130.4 Million bytes
Embedded Controller: .......... AT or SCSI
Number of Disks: .............. 2
Data Surfaces: ................ 4
Data Heads: ................... 4
Servo: ........................ Embedded
Tracks per Surface: ........... 1,156
Track Density (average): ...... 1,800 tpi
Track capacity (formatted): ... 21,504
Bytes per Block: .............. 512
Blocks per drive: ............. 254,688
Sectors per track: ............ 42 physical

PERFORMANCE (Typical):

Seek times* (ms)
     Track to track: .......... 4
     Average: ................. 15
     Maximum: ................. 30

Average latency (ms) .......... 8.55
Rotation speed ................ 3,524 RPM
Controller overhead ........... 1 ms

Data transfer rate (Mbytes per sec)
     To/from media ............ 1.5
     To/from buffer (AT) ...... 6.0
     To/from buffer (SCSI) 5 (sync) 3 (async)

Start time/power up (0 - 3,524 RPM)
     Typical .................. 3 sec
     Maximum .................. 10 sec

Start/stop cycles: ............ 20,000 min

Interleave: ................... 1:1

Buffer Size: .................. 64K

Interface: .................... AT

Recording Method: ............. 1,7 RLL

Recording density - ID: ....... 34,087 bpi

Flux density - ID 
(flux reversals per inch): .... 25,565


POWER REQUIREMENTS (Typical):

MODE		+12V DC +8%         +5V DC +5%          POWER
----            -----------         ----------          -----

Spin-up         1 A Avg Peak        150 mA Avg Peak     10.2W Peak
R/W             280 mA              290 mA              4.8W
Idle            120 mA              70  mA              1.8W 
Standby         10  mA              90  mA              0.7W
Sleep           0   mA              20  mA              0.1W

Physical:
	Height: ............... 1.00"  (2.54 cm)
        Length: ............... 5.75"  (14.61 cm)
        Width: ................ 4.00"  (10.16 cm)
        Weight: ............... 1.2 lbs. (.57 kg)


ENVIRONMENTAL:

Temperature
        Operating: ............ 5 degrees C to 50 degrees C
        Non-operating: ........ -40 degrees C to 65 degrees C
        Thermal gradient: ..... 20 degrees C per hour max

Humidity
        Operating: ............ 8% to 80% non-condensing
        Non-operating: ........ 8% to 80% non-condensing
        Maximum wet bulb: ..... 26 degrees C

Altitude (Relative to sea level)
        Operating ............. -200 to 10,000 feet
        Non-operating ......... 40,000 feet max


RELIABILITY & MAINTENANCE:

MTBF: ......................... 150,000 hours (POH),predicted at 35 degrees C)
MTTR: ......................... 30 minutes typical
Preventive maintenance: ....... None
Component Design Life: ........ 5 years (minimum)

Data Reliability
   Hard read errors ........... ^10 per 10-13 bits read

Shock and Vibration
   Shock measured at half-sine pulse.  Vibration measured at swept sine,
   1 octave per minute.

   Non-operating shock: ....... 70Gs,  1ms
   Operating shock: ........... 10 Gs, 11ms 
                                (without non-recoverable errors)

   Non-operating vibration: ... 5 - 11 Hz  0.320" (double amplitude)
                            ... 11 - 300 Hz  2G's, 11 ms (without non-
                                recoverable errors)

   Operating vibration: ....... 5 - 11 Hz  0.160" (double amplitude)
                        ....... 11 - 300 Hz  1 G peak amplitude

Accoustic Noise ............... 42dBa max. at 1 meter        

===============================================================================

  The 7000AI series drives, were manufactured specifically for 
  "I"BM. IBM had the jumpers changed on the early models to fit 
  their specifications. Part of IBM's spec. was that the drive 
  be "CAM spec", therefore J19 is used only as a spare jumper.

  At some point IBM changed their mind and started using these 
  drives just the way we normally make them. BUT, we don't have 
  ANY info on what TLAs go with what drives. So try it both ways.
  To the best of my knowledge all other AI drives, 7213AI, 7170AI, 
  etc. are jumped "normally": 

      7120AI JUMPER DESIGNATIONS      J20J19J18J17J16J15J14J13J11
+-------------------------------------+---+---+---+---+---+---+---+---+---
 Master/Slave                                                   
  Only drive in single drive system*  O  J                      
  Master in dual drive system         O  J                      
  Slave in dual drive system          J  O                      
+-------------------------------------+---+---+---+---+---+---+---+---+---
 ECC Bytes                                                      
  4 Bytes*                                  J                   
  7 Bytes                                   O                   
+-------------------------------------+---+---+---+---+---+---+---+---+---
 Drive Model Number                                             
  7060A                                        O                
  7120A*                                       J                
+-------------------------------------+---+---+---+---+---+---+---+---+---
 Idle Mode Latch                                                
  Option Disabled*                                O             
  936x16x17 CHS Auto-Detect Setting               J             
+-------------------------------------+---+---+---+---+---+---+---+---+---
 Reserved for Factory                                           
  Normal Operation*                                  O          
  Disables ECC test                                  J          
+-------------------------------------+---+---+---+---+---+---+---+---+---
 J13, J14, & J15                                       N/AN/AN/A
+-------------------------------------+---+---+---+---+---+---+---+---+---+
  J=Jumpered O=Open *=Default
                                                              +---+       
                                                              0 0J11    
                                              J20 J18 J16     0 0J13    
                                             +-+---+---+-+    0 0J14    
                                              0 | | | |     0 0J15    
                                              0 | | | |     +---+       
                                             +---+---+---+                
                                                J19 J17                   
                                           -------------------------------+
           Maxtor 7120AI Jumper Designation And Parameters

                 7120A ia a trademark of Maxtor Corporation.
                AT is a registerd trademark of IBM Corporation.
               Specifications subject to change without notice.
                     Copyright 1992-96 Maxtor Corporation.
                         Rev D     2/2/96    Anderson
==============================================================================