PT. Cahayamulia Langgeng We’ve got it under control!

The application for GSM-4

 

Manual

 

 

 

 

• Burglar alarms

• Door control / Access control

• Temperature control

Company: PT.Cahayamulia Langgeng Address :Jl.Pasir Kencana II/A-14,Pasir Pogor Indah, Bandung 40287, Indonesia

Tel: +62 (0)22. 7561877, Website: www.geocities.com/gsm4control, E-mail: [email protected]

 

1 The application for AutoLog GSM-4 - Introduction

GSM technology can be used effectively with AutoLog GSM-4. You can open doors and

control alarms and temperature with GSM technology, which works all most everywhere

in the world.

1.1 Main features

• Burglar alarms

• Door control / Access control

• Temperature control

1.2 Door control / Access control

The doors and gates can be opened free of charge with AutoLog GSM-4 and controlling

is always safe - the device accepts controls only from recognized telephone numbers.

You can set max. 48 different telephone numbers in the memory of AutoLog GSM-4 in

this application. The numbers can be either GSM numbers or regular numbers from

which controlling is allowed. Two doors, gates or any other electromechanical devices

can be connected to AutoLog GSM-4. The doors can be opened also with the defined

text messages.

Function examples:

You call to the regular number of AutoLog GSM-4. When the device receives the call, it

recognizes the number and compares it to the telephone number list of AutoLog GSM-4

and controls relay output 0 on for 30 seconds. Now you have 30 seconds to go through

the door 0.

You call to the data number of AutoLog GSM-4. When the device receives the call, it

recognizes the number and compares it to the telephone number list of AutoLog GSM-4

and controls relay output 1 on for 30 seconds. Now you have 30 seconds to go through

the door 1.

1.3 Burglar alarms

There are 4 separate alarm inputs in AutoLog GSM-4. The alarm inputs can be

connected to detectors, door magnet or other sensors with closed circuit.

Alarm control can be switched on by sending the defined text message ( $ON* ) to

AutoLog GSM-4.

Alarm control can be switched off by sending the defined text message ( $OFF* ) to

AutoLog GSM-4.

If alarm occurs then AutoLog GSM-4 sends the alarm text message to telephone number

0 ( first telephone number in the memory of the device ).

The status of the device can be checked anytime, anywhere where GSM technology is in

use.

BURGLAR

ALARM !

1.4 Temperature control

There can be Pt100 temperature sensor connected to AutoLog GSM-4. The measuring

range is -50…+150 °C. The temperature alarm limits can be set with the text messages.

AutoLog GSM-4 sends alarms to telephone number 0.

TEMPERATURE

LOW LIMIT ALARM !

+ 12.75 Celsius

1.5 Real time report

You can ask the real time report from AutoLog GSM-4 to your mobile phone by sending

the defined text message. The report includes the status of temperature and the status

of alarm inputs.

If the status of the door is 1, the door is locked. If the status is 0, the door is open.

If the status of the alarm input is 1, there is no active alarm. If the status is 0, there is an

alarm situation.

TEMP. + 23.50C

DOOR0 = 1

DOOR1 = 1

INPUT0 = 1

INPUT1 = 0

INPUT2 = 1

INPUT3 = 0

1.6 This application can be used in several targets

• Buildings

• Offices

• Vehicles

• Boats

• Stores

1.7 Benefits

• Fast implementation

• Cheap to use

• On-line changes via GSM network

• Direct connection to your mobile phone

• Wireless RTU is working all the places where is GSM network.

1.8 General

PT.Cahayamulia Langgeng offers integrated machine and device controlling systems for both end

and OEM users.

AutoLog GSM-PLCs can be used as automation and remote use devices in small or

middle size targets. Easy solutions for machine and device controls and other

( M2M = Machine to Machine ) applications.

AutoLog GSM-PLC monitors and controls process – sends information to right people, to

control room or to Internet application.

1.9 The device specifications of AutoLog GSM-4

The application with AutoLog GSM-4 Case, product code: 900728

• IP20

• 4 digital inputs ( 24VDC / max. 8mA )

• 2 relay outputs ( Max. 250VAC / 30VDC / 2A )

• 1 analogue input ( It includes calibrated for Pt100 sensor, -50…+150 °C, product code: 900781 )

• Integrated GSM modem and antenna

• GsmProgrammer ( Programming tool for AutoLog GSM-PLCs )

• Telephone number list: even 100 different telephone numbers ( 48 different telephone numbers in this application )

• The application for AutoLog GSM-4

• We recommend that user provides Mascot battery eliminator, e.g. Mascot 9829 ( 12VDC/19,5W )

• Complete product and application support: [email protected]

• Programming cable

• Programming manual CD The application with AutoLog GSM-4 Unit, product code: 900732:

• IP65 enclosure

• Battery/UPS 12 VDC

• 4 digital inputs ( 24VDC / max. 8mA )

• 2 relay outputs ( Max. 250VAC / 30VDC / 2A )

• 1 analogue input ( It includes calibrated for Pt100 sensor, -50…+150 °C, product code: 900781 )

• Integrated GSM modem and antenna

• GsmProgrammer ( Programming tool for AutoLog GSM-PLCs )

• Telephone number list: even 100 different telephone numbers ( 48 different telephone numbers in this application )

• The application for AutoLog GSM-4

• We recommend that user provides Mascot battery eliminator, e.g. Mascot 9829 ( 12VDC/19,5W )

• Complete product and application support: [email protected]

• Programming cable

• Programming manual CD

2 Installation

2.1 SIM card

At first open the plastic IP65 enclosure ( four screws / AutoLog GSM-4 Unit ). SIM card

is installed on GSM module ( check the installation picture 2.7 ). Ensure before installing

that default PIN code is 0000, because AutoLog GSM-4 supposes that PIN code is 0000.

You can do that checking with your mobile phone.

SIM card properties have to include calling and text message features. The calling

features have to include also the data and the fax telephone numbers in addition to the

regular telephone number. So you have three telephone numbers to the device ( three

free of charge controls ). If there are not the data and fax telephone numbers, you can

do the same controls also with the defined text messages.

2.2 Connections to electromechanical locks

There are two places for the electromechanical locks. The locks are connected to the

relay outputs of AutoLog GSM-4. Connect your door0/lock0 to the relay output0.

Connect your door1/lock1 to the relay output1. The locks, which will be connected, have

to be able to use 12 VDC, because the locks get power from AutoLog GSM-4 and it uses

12 VDC( check the installation picture 2.7 ).

2.3 Connections to alarm inputs

There are four separate alarm inputs in AutoLog GSM-4. Sensors, detectors or door

magnets have to also use 12 VDC ( check the installation picture 2.7 ).

2.4 Temperature sensor

Temperature sensor has to be Pt100 sensor ( four separate wires ) .

2.5 Power

Power input has to be 12 - 15 VDC. Note! Check how many amperes are needed for

the electromechanical locks and sensors - power input has to be at least 20 W, e.g.

Mascot 9829 ( 12 VDC / 19,5 W )

2.6 Battery

During general power failure the device can work a couple of hours with the battery 12 V.

2.7 The installation picture

The power input wires of electric door lock ( this system is for 12 VDC electric locks )

( Relay outputs Max. 250 VAC / 30 VDC / 2 A )

Power input 12 - 15 VDC,

At least 20 W,

E.g. Mascot 9829

ACC -

ACC +

AC/DC

AC/DC

Battery

12 V

- +

RUN SERV

CON101

MOD302

CON201

CON202

JUMPER

CON1

IC1

IC7 IC6

B1

0 1 2 3

1 2 3 4 5

0 1

MODEM

RX TX

-

SIM-card

CON102

ANTENNA

Opening switches (N0=alarm):

INPUT0 = Detector/contactor 0

INPUT1 = Detector/contactor 1

INPUT2 = Detector/contactor 2

INPUT3 = Detector/contactor 3 Pt100 sensor -50...+150C

3 General settings

3.1 Telephone numbers

There can be max. 48 different telephone numbers in the phone book of AutoLog GSM-4

from place 0 to place 47. User can control these phone numbers with password. The

password default setting is 0000.

-----------------------------------------------------------------------------

For example all phone numbers can be read by sending this text message to the device:

0000 NUM A?*

-----------------------------------------------------------------------------

User can set phone numbers by sending the defined text message to the device. At first

password, then NUM command, then the place of the telephone number and last the

telephone number.

• Note! Set your mobile phone number with and without the land code, because some features work with land code and some without.

• Note! Text messages alarm will be sent only to telephone number 0 ( place 0 ) and it can be without or with the land code.

For example phone number 0227561877 to place 0 ( this telephone number receives also alarms ):

0000 NUM 0=0227561877*

Set the same telephone number also with the land code ( the land code of Indonesia is +62 ):

0000 NUM 1=+62227561877*

Set other telephone numbers in the same way to the different places, for example:

0000 NUM 2=0215330346*

…and with the land code:

0000 NUM 3=+62215330346*

User can delete a phone number from the phone book with this text message:

For example the phone number removing from place 0:

0000 NUM 0=*

-----------------------------------------------------------------------------

• We recommend that you will make the document of the phone numbers.

3.2 Password changing

The default password for the device is 0000. You need not to change it. But if you want

to change it, you can do it.

Format:

OldPassword PSW NewPassword NewPassword*

-----------------------------------------------------------------------------

E.g, change password 0000 to 3857:

0000 PSW 3857 3857*

-----------------------------------------------------------------------------

Response from device:

# PSW OK ; Password changed successfully

OR

# PSW BAD ; If the password didn't change!

-----------------------------------------------------------------------------

• Be careful with password changing - if you forget the password, you can not get contact to AutoLog GSM-4!

3.3 PIN code changing

The default PIN code for the SIM card is 0000. You need not to change it. But if you want to change it, you can do it.

Format:

OldPinCode PIN NewPinCode NewPinCode*

-----------------------------------------------------------------------------

E.g, change PIN code 0000 to 3857:

0000 PIN 3857 3857*

-----------------------------------------------------------------------------

Response from device:

# PIN OK ; PIN code changed successfully

OR

# PIN BAD ; If the PIN code didn't change!

-----------------------------------------------------------------------------

• Be careful with PIN code changing - if you forget the PIN code, you can not get

contact to AutoLog GSM-4!

4 Door control / Access control

• Amount of users can be max. 24 / 48 pcs ( depend on settings ).

• Device can control two electromechanical door locks ( two relay outputs ).

• Doors can be controlled with the text messages or calls ( regular, data, fax ).

• Door controlling is possible only from identified phone numbers.

• User can set the door delay time ( = the time for how long the door is ON ).

• Door delay time can be set to 0-65535 seconds.

• Default setting for door delay time is 10 seconds.

4.1 Opening doors with the text messages

• Open the door0 with this text message:

$DOOR0*

• Open the door1 with this text message:

$DOOR1*

• Open all doors with this text message:

$DOORS*

4.2 Opening doors with calls

• Open the door0 by calling to the regular telephone number of the device.

• Open the door1 by calling to the data telephone number of the device.

• Open both doors by calling to the fax telephone number of the device.

4.3 Delay setting for opening doors

User can read the delay settings by sending this text message to the device:

$READDOOR*

The response from device, for example:

THE DOOR DELAYS: DOOR0=35 seconds, DOOR1=20 seconds

-----------------------------------------------------------------------------

User can set the delay settings with the text message. For example 20 seconds delay

for the door0 and 15 seconds delay for the door1:

$SETDOOR=20=15*

Response from device:

THE DOOR DELAYS: DOOR0=20 seconds, DOOR1=15 seconds

• Always set the both delays at the same time.

5 Burglar alarms

• There are 4 separate alarm inputs in AutoLog GSM-4.

• Detectors, door magnets or other sensors with closed circuit (=normal situation)

can be connected to alarm inputs.

• If alarm occurs then AutoLog GSM-4 sends the alarm text message to telephone

number 0 ( first telephone number in the memory of the device ).

5.1 The alarm system ON / OFF

Alarm control can be switched on by sending the defined text message:

$ON*

...and user gets back this text message:

ALARM SYSTEM SWITCHED ON

-----------------------------------------------------------------------------

Alarm control can be switched off by sending the defined text message:

$OFF*

...and user gets back this text message:

ALARM SYSTEM SWITCHED OFF

5.2 Four separate alarm messages

• BURGLAR ALARM! INPUT 0

• BURGLAR ALARM! INPUT 1

• BURGLAR ALARM! INPUT 2

• BURGLAR ALARM! INPUT 3

5.3 Hysteresis delays for the alarms

This delay defines how long time a contact has to be opened for an alarm to occur.

The default setting is 0 seconds for every alarm inputs.

You can set the hysteresis delays for every alarm inputs by sending this text message:

Format:

$SETALARMHYSTERESIS=INPUT0=INPUT1=INPUT2=INPUT3*

For example:

$SETALARMHYSTERESIS=75=50=0=0*

Response from the device:

THE HYSTERESIS DELAYS: INPUT0=75s, INPUT1=50s, INPUT2=0, INPUT3=0s

• Settings can be set to 0-65535 seconds.

5.4 SMS alarm delays for alarm sending

This delay defines how quickly an alarm text message will be sent after alarm situation has occurred. The default setting is 30 second for every alarm inputs, so user has 30 seconds to shut down the alarm system before it sends the alarm text message.

You can set the SMS alarm delays for every alarm inputs by sending this text message:

Format:

$SETSMSALARMDELAYS=INPUT0=INPUT1=INPUT2=INPUT3*

For example:

$ SETSMSALARMDELAYS=3=120=57=1*

Response from the device:

THE SMS ALARM DELAYS: INPUT0=3s, INPUT1=120s, INPUT2=57s, INPUT3=1s

5.5 Alarm delays reading

You can read the previous alarm delay settings by sending this text message to the

device:

$READALARMDELAYS*

6 Temperature control

• There can be Pt100 temperature sensor connected to AutoLog GSM-4

• The measuring range is -50…+150 °C.

• The temperature alarm limits can be set with the text messages.

• AutoLog GSM-4 sends alarms to the telephone number 0.

• The default setting for LOW LIMIT ALARM is 5 °C

• The default setting for HIGH LIMIT ALARM is 38 °C

• Temperature has to be at least 60 seconds over limit to induce alarm.

• User can increase hysteresis between 0 and 65535 minutes

6.1 Temperature alarm messages

• TEMPERATURE LOW LIMIT ALARM! + 3.50C

• TEMPERATURE HIGH LIMIT ALARM! + 47.75C

6.2 Temperature alarm delay settings – setting

User can change temperature alarm delay settings by sending this text message:

For example ( at first for the low limit and then for the high limit ):

$SETTEMPDELAYS=16=16*

Response from the device:

TEMPERATURE ALARM DELAY SETTINGS: LOW LIMIT=16min, HIGH LIMIT=16min

6.3 Temperature alarm delay settings – reading

User can read temperature alarm delay settings by sending this text message:

For example:

$READTEMPDELAYS*

Response from the device:

TEMPERATURE ALARM DELAY SETTINGS: LOW LIMIT=16min, HIGH LIMIT=16min

6.4 Temperature alarm limit settings – setting

User can change temperature alarm limit settings by sending this text message:

For example ( at first the low limit and then the high limit ):

$SETTEMPLIMITS=15=30*

Response from the device:

TEMP.ALARM LIMIT SETTINGS: LOW LIMIT=15C, HIGH LIMIT=30C

• Note! Negative temperature alarm limits can not be set!

6.5 Temperature alarm limit settings – reading

User can read temperature alarm limit settings by sending this text message:

For example:

$READTEMPLIMITS*

Response from the device:

TEMP.ALARM LIMIT SETTINGS: LOW LIMIT=8C, HIGH LIMIT=45C

7 Real time report

You can ask the real time report from AutoLog GSM-4 to your mobile phone by sending

the defined text message. The report includes the status of temperature, the status of

the doors and the status of the alarm inputs.

• If the status of the door is 1, the door is locked.

• If the status of the door is 0, the door/lock is open.

• ALARM SYSTEM=1 ( the system on )

• The status of alarm input is 1 = normal situation.

• The status of alarm input is 0 = alarm situation.

User can receive the real time report by sending this text message to the device:

$REPORT*

Response from the device to your mobile phone, for example:

TEMPERATURE=+27.40C, DOOR0=1, DOOR1=0, ALARM SYSTEM=1, INPUT0=0,

INPUT1=1, INPUT2=1, INPUT3=1

8 Offer: AutoLog GSM-4 12.01.2004

Customer:

Address:

Tel:

Fax:

E-mail:

Dear Sir,

Here is offer for AutoLog GSM-4. Delivery time is 4-5 weeks.

The dev ice specifications of AutoLog GSM-4 Case + The application for AutoLog GSM-4

• IP20

• 4 digital inputs ( 24VDC / max. 8mA )

• 2 relay outputs ( Max. 250VAC / 30VDC / 2A

• 1 analogue input ( Includes calibrated Pt100 module, -50…+150 °C, product code: 900781 )

• Integrated GSM modem and antenna

• GsmProgrammer ( Programming tool for AutoLog GSM-PLCs )

• Telephone number list: even 100 different telephone numbers

( 48 different telephone numbers / 24 users in this application )

• Programming cable

• Programming manual CD

• The application for AutoLog GSM-4

• We recommend that user provides Mascot battery eliminator, e.g. Mascot 9829 ( 12VDC/19,5W )

Indonesia Price : (Rp) 13,755,000.00 FOB. Bandung

For other ASEAN countries: USD 1,657 (FOB. Bandung, Indonesia)

 

 

Hosted by www.Geocities.ws