Model : 943
Series Relay |
|
Features: |
 |
UL, CSA & TUV
safety approval.
|
 |
TV-5 rated available.
|
 |
UL Class F (155 )
coil insulation type available.
|
 |
Nominal power
360 mW.
|
 |
Operating power
200 mW.
|
 |
Heavy current
up to 12 Amps.
|
|

|
|
UL FILE NO: E162117
CSA FILE NO: LR107041-1
TUV FILE NO: R9653010
|
|
| |
|
Ordering
Info |
|
Model Number :
|
943 - 1A -
12 - D - S - F |
|
(2)
(3) (4) (5) (6)
|
2)
Contact Arrangement :
1A=1 Form A (SPST-NO)
1B = 1 Form B (SPST-NC)
1C = 1 Form C (SPDT)
|
3) Coil
Voltage :
3~48V |
4) Coil Type
:
D:DC |
5) Enclosure
:
Nil = GeneralType
S = Sealed Type |
6) Type of
Insulation :
Nil = Class B
F = Class F |
|
| |
| |
|
Coil
Ratings at 20 deg C |
|
COIL
TYPE
|
Coil Nominal
Voltage(V)
|
Coil
Resistance
(10%)
|
Pick-Up
Voltage(V)
|
Drop-Out
Voltage(V)
|
Norminal
Current
(mA)
|
|
DC
Standard Coils
|
3
|
25
|
2.25
|
0.3
|
120
|
|
5
|
70
|
3.75
|
0.5
|
71
|
|
6
|
100
|
4.5
|
0.6
|
60
|
|
9
|
225
|
6.75
|
0.9
|
40
|
|
12
|
400
|
9
|
1.2
|
30
|
|
18
|
900
|
13.5
|
1.8
|
20
|
|
24
|
1600
|
18
|
2.4
|
15
|
|
48
|
6400
|
36
|
4.8
|
7.5
|
*Max Continuous
Voltage at 20C:130%
of Coil Nominal Voltage.
|
|
| |
| |
|
Characteristics |
|
Electrical Life |
1X105(12A 125VAC
3X103) |
| Mechanical
Life |
1X107 |
| Initial
Insulation Resistance |
Min.
100MX
500VDC |
| Contact
Resistance (Initial) |
X
ohm |
| Operate
Time |
X10ms
|
| Release
Time |
X5ms |
| Initial
Dielectric Strength |
50/60Hz
700VAC 1 min. (between open contact)
50/60Hz 1500VAC 1 min. (between
all conductors) |
|
Vibration Resistance |
Malfunction: 10 to
55Hz at Double Amplitude of 1.5mm
Destructive: 10 to 55Hz at Double
Amplitude of 1.5mm |
| Shock
Resistance |
Malfunction:
10G (11ms) / Destructive: 100G (6ms) |
| Ambient
Temperature |
-30C~+60C |
| Relative
Humidity |
85%
at 40C |
| Unit
Weight |
Approx.10g |
|
| |
| |