Fiero C 500 Connector
| PIN # |
USE |
Wire Colour |
Description |
How to Modify |
| A2 |
Ground |
BLK |
To Ground |
|
| A4 |
Start |
YEL |
Hot in start. Connect to gear selector (auto only) |
|
| B3 |
Charge |
BRN |
Charge indicator light. Connect to BRN alt wire |
|
| C1 |
Reverse |
DK BLU |
Reverse light power feed. Connects to auto gear selector or manual reverse switch Fuse 10A |
|
| C2 |
Temp guage |
DK GRN/WHT (v6) |
Connect to temp sender 1365 Ohm at 100 deg, 55 Ohm at 260 deg |
|
| C3 |
Tachometer |
WHT |
Connect to coil or ign module |
|
| D1 |
Fan Switch |
DK GRN/WHT |
Connect to grounding fan switch or to ECM temp output |
|
| D2 |
Fan Switch |
LT GRN/BLK |
Same as above (2 speed fan models) |
|
| D3 |
Temp Lamp |
DK GRN |
Connect to grounding Temp switch or ECM temp output |
|
| E1 |
Reverse |
LT GRN |
Connect to auto selector or manual rev switch |
|
| E2 |
Start |
PPL |
Connect Hot in start |
|
| E3 |
Ignition |
PNK |