Overview and
Specifications
OverView.
The Autronic SMC Sequential Engine Management System is a compact
engine management control for all engine performance upgrades.
A user friendly "IBM" compatible laptop program allows the
user to select the degree of sophistication required for each
application. This program, in combination with intelligence within
the management system, allows the user to select the finest
calibration detail required to match the application, in absolute
minimum of time.
This program provides the means of interrogating the engine
management system enabling speedy diagnosis and calibration.
Usage.
These systems can cater for the requirements of virtually any spark
ignition engine, including the following.
i. High output supercharged or turbocharged
engines, with either multi point and/or center point injection.
ii. Rotary (Wankel) and two stroke engines.
ii. Engines having uneven firing sequences such as
2 and 4 cylinder "V" configuration motor cycle engines
and V6 motor vehicle
engines.
IMPORTANT:- Please note that this product is intended for high
performance motor sport applications and compliance with statutory
regulations when used on public roads cannot be guaranteed.
Features.
1. a. Eight injector drivers for
full sequential operation on engines up to eight cylinders. May be
set for
'semi-sequential'
operation on engines having more than 8 cylinders. e.g:- 12 cylinder
engine using
6
groups of 2 two cylinders.
b. All
injector types catered for (0.9 ohm to 16 ohm coil resistance).
Specify unit fitted with
optional
high current injector drivers for 0.9 ohm or twin injector
applications.
2. User choice of manifold absolute pressure or throttle position as
engine load input. Internal absolute
pressure sensor for simplified installation
0 to 200 kpa (0 to 29.4 PSI) and 0 to 300 kpa (0 to 44.1 PSI)
available from stock. 0 to 450 kpa (0 to
66.1 PSI) available on request.
3. Single coil distributor, twin coil distributor or muilticoil
distributor-less ignition configurations are possible on
most engines.
4. Fitted with environmentally sealed connector the standard unit is
splash proof. Units are available with double
environmental sealing for use in the most
arduous of applications (e.g:- rally, off-road and marine).
5. Auxiliary output function that can be used for any of the
following:
i. Closed loop
(feedback), boost control for turbocharged engines with rpm and
temperature
dependent
calibration characteristic.
ii. Closed loop
(feedback) idle speed control.
iii. Control of engine
cooling fan.
iv. Programmable on/off
control for solenoid or relay driving that operates according to
engine speed
and
load (eg:- can be used for gear shift control or light, over rev
indicator, inlet camshaft timing
selection
or control of a supplementary electric fuel pump that augments
mechanical fuel pump
delivery
at low engine rpm only).
v. Fuel used pulse
output to electric or electro-mechanical counter with resolution of
0.1 liter (or use
with
trip computer).
vi. Or even more
sophisticated control function such as servo control of auxiliary
butterfly for
turbocharged
applications requiring precise throttle control and minimum turbo
lag.
6. Exhaust oxygen sensor input for sensing air/fuel ratio.
Connect either a Bosch narrow band O2 sensor or for
more demanding applications a
Bosch wide band O2 sensor and Autronic Analyzer. The low cost narrow
band sensor requires no
interface adapters or expensive air/fuel ratio meters, and offers moderate
accuracy and tolerance to leaded
fuels. This function can be used to monitor air/fuel ratio during
engine tuning or can be used for
feedback control of air/fuel ratio for applications requiring
exhaust catalytic conversion (feature
available on request).
7. Diagnostic/Error indicator of sensor or ECU fault
conditions with memory for detection of intermittent fault
conditions. An external light may also
be connected for remote indication of abnormal operation.
8. Precise spark advance control strategy for both static and
dynamic operating conditions.
9. Unique calibration strategy allows accurate control of fuel
delivery under both acceleration and deceleration.
10. User selectable spark and fuel delivery strategy for abnormal
engine operation conditions to minimize
possibility of engine
damage whilst still maintaining engine operation.. (eg:- over heated
or over boosted).
11. Comprehensive limp-home functions with user selectable default
settings that ensure engine operation can
continue after sensor
failure has occurred.
12. Full compensation of engine control parameters for engine
operation at any altitude (fuel delivery, ignition
timing and boost pressure).
13. Adaptive learning (with memory) to minimize the number of user
setups required and to provide optimal
control of air/fuel ratio, boost
pressure and idle stability.
14. Rev limiter with soft characteristic that uses a combination of
fuel delivery and spark control.
15. Fuel pump safety shutoff. Pump stops 3 to 4 seconds after the
engine stops.
16. Unit is ultra light weight/compact yet has sufficient drive
capacity for high power continuous duty
applications. (one unit OK for
all applications from motor cycle to large capacity twin turbo
engines).
17. Optional interface unit to allow sequential operation without
the need for separate crank/camshaft sensors or
special multi-sensor
distributor.
Interface
Requirements.
INPUTS
Sensors 1. Ignition input Hall effect,
(Also available for direct connection to magnetic reluctor type
pick-ups).
2.
No. 1 cylinder reference. (Also available for
direct connection to magnetic reluctor type
pickups).
3.
Barometric pressure. (Internal to ECU).
4.
Manifold pressure. (Internal to ECU).
5.
Throttle position.
6.
Intake air temperature.
7.
Engine coolant temperature.
8.
Exhaust oxygen. (or optional Wide Range Air/Fuel
Ratio Sensor).
9.
Idle mixture trim. (Internal to ECU and
screwdriver adjustable from outside).
OUTPUTS
Main 1. 8
off injector driver. (Optional 2 injectors per driver).
2.
Ignition output.
Open
collector output to any of the following:
1.
Single coil high energy ignitions: Bosch 7 pin,
Mitsubishi 3 pin.
2.
Autronic Capacitor Discharge Ignition.
3.
MSD 6A etc..
(4
outputs are available allowing multi coil distrubtor-less ignition
for applications on
engines
up to 8 cylinders).
Auxiliary 1. Fuel pump/injector fuel
shut off safety relay.
2.
Multifunction on/off or pulse width modulation
output for either:
i.
Engine cooling fan relay.
ii.
Idle speed actuator. (Variable duty cycle single pole
type, eg:- Bosch).
iii.
Turbocharger wastegate control valve. (SEM, most OEM types or
Autronic low or high
capacity).
iv.
Turbocharger auxiliary butterfly control motor.
v.
General purpose duty cycle output with user define
characteristic.
vi
Fuel used pulse output. (for trip computer function).
SERIAL I/O
1.
Communications with "IBM"
compatible computer for calibration, fault diagnosis.
Specifications.
| Microcomputer |
|
Intel 16 bit running @ 16Mhz |
| Supply Voltage |
Normal operation
Safe limits
|
6.2V to 23V DC continuous
+/- 24V (5 min)
+/- 80V alternator load dump (0.5 sec).
+/- 1000V inductive spike (10 usec) |
| Current Drain |
@ Engine idle
@ Max Engine Load
|
< 1 Amp.
< 16 Amp (less depending on injector
type and number. |
Operating Temperature Range
|
Min
Max
|
- 40 deg C.
+ 85 deg C. |
| Engine Cylinder Number Settings |
Number of cylinders
|
1, 2, 3, 4, 5,
6, 7, 8, 10, 12, 14 and 16 |
| Engine RPM Range |
0 to 30,000 RPM
0 to 16,000 RPM
0 to 15,000 RPM
|
Engines up to 4 cylinders
Engines up to 5 to 8 cylinders.
Engines 10 to 16 cylinders. |
| Injection Duration Timing |
Min
Max
Accuracy
Setting resolution
|
0.7 msec.
30 msec.
+/- < (10 usec + 1%)
0.1% approx. |
| Injection Timing |
Range
Accuracy
Setting resolution
|
0 to 720 deg (crank angle).
+/- < (1.4 deg + 0.3 msec).
2.8 deg. |
| Ignition Timing |
Advance range
Accuracy
Setting resolution
|
0 to 45 deg (crank angle).
+/- 0.2 deg (crank angle).
0.5 deg (crank angle). |
| Fuel Delivery and Ignition Mapping |
No. Load sites
No. RPM sites
|
16 (max).
Both Load and RPM
sites
32 (max). are
freely selectable. |
| Size |
L * W * H
|
157 * 122 * 35 mm
180 * 128 * 35 mm (overall, including
mounts & connector) |
| Weight |
|
0.5 kg |
| Connectors |
|
36 way 'AMP' water and dust
proof socket |
|