| ACCESSORIES OF CENTRAL MEDICAL GAS PIPELINE | |||||||||||||||||||||
| BPC OXYGEN FLOWMETER Study flow meter with accurate measurement of the flow. � Chromium plated brass body � Metering tube and cover made of unbreakable polycarbonate � Micrometrical regulation of flow by needle valve � Back pressure compensated � Inlet filter provided � Flow rate: 0 �12 LPM for oxygen Accuracy: max 10% of actual valve Maintenance free. Easy to disassemble and reassemble for cleaning, checking and replacement of the metering tube. WARD VACUUM UNIT WITH 600/ 1000 /2000 ml JAR � It is in two parts one is regulator and the other one is a jar with cap � Regulator is consisting of on off knob and another regulation knob for increasing or decreasing the vacuum. � Regulator has a gauge calibrated between 0 to 700 ml of Hg. � Jar is made up of polycarbonate material � Jar is auto clavable up to 134 deg centigrade � Jar cap has a inbuilt non-return valve which stop any liquid flow after a certain lave SINGLE STAGE REGULARATOR � Consist of brass body � Consist of brass bonnet � Body consist of kit nozzle valve � Valve body consist of viton seat � Regulator pressure preset at 4.22 Kg/cm2 (60 PSI) � Pressure can be changed through an adjustable screw � Consist of a pressure gauge of EMPL � Pressure gauge calibrated from 0 to 250 Kg/cm2 � Safety pressure of the regulator set at 80 PSI � Flow at 4.22 Kg/cm2 is 400 ltr /min. DOUBLE STAGE REGULARATOR � Consist of brass body � Consist of brass bonnet � Body consist of kit nozzle valve � One kit nozzle valve for upper chamber � One lit nozzle valve for lower chamber � Pressure shall be reduced in two stages � Lower kit nozzle valve pressure is preset � Upper chamber pressure is adjustable as per � output required � Two pressure gauges one shows the cylinder pressure � Other shows the line pressure which is set ANTISTATIC HIGH PRESSURE TUBING � Oxygen whit � Vacuum Yellow � Nitrous French blue � Air Black OXYFAILURE ALARM SINGLE GAS � Alarm gets actuated at 3 Kg/cm2 or below � It is an audio visual alarm system � Alarm sound can be continuous or intermittent � Pressure is actuated by a pneumatic pressure switch � Audio visual system is actuated by AC current Epson Trade Link 19b 1st floor, Arjun Nagar, SJE, New Delhi 110029 Ph. 01126184798, 9313749194 E-mail :[email protected] |
|||||||||||||||||||||
| Our Products: | |||||||||||||||||||||
| BPC flowmeter | |||||||||||||||||||||
| Vacuum unit with jar | |||||||||||||||||||||
![]() |
|||||||||||||||||||||
| Regulator Single/ Double Stage | |||||||||||||||||||||
| Oxyfailure alarm | |||||||||||||||||||||
| EPSON TRADE LINK | |||||||||||||||||||||
| Contact Person: Pushpa Dhar Tel: 91-011-26184798 Mobile : 9313749194 | |||||||||||||||||||||
| Name: | Epson Trade Link | ||||||||||||||||||||
| Email: | [email protected] | ||||||||||||||||||||
|
|
|||||||||||||||||||||