Strengthening of an existing reinforced concrete structure


 

Appendix A:

·   Note that all values in shaded cells were the experimental reading before adjustment.

·   All strains readings in tables and figures are in micro strain unit.

Indoor Samples (ID):

ID 1

Steel

Failed at 9 kN

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

0

0

8.04

-15

0

 

1

0.07

8.11

6

21

 

3

1.16

9.2

43

58

 

5

1.24

9.28

103

118

 

9

2.76

10.8

2655

2670

 

10

3.94

11.98

 

 

 

10.5

6.86

14.9

 

 

 

11

9.82

17.86

 

 

 

11

13.66

21.7

 

 

 

10

16.36

24.4

 

 

 

8

17.88

25.92

 

 

 

Table 4.1: Steel reinforced beam (Indoor)

ID 2

Plain + 1FRB

Failed at 26 kN

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

9.21

 

0

-194

1

0.06

9.27

 

12

-182

3

0.15

9.36

 

40

-154

5

0.22

9.43

 

61

-133

7

0.27

9.48

 

84

-110

10

0.35

9.56

 

190

-4

12

0.41

9.62

 

328

134

15

0.56

9.77

 

727

533

18

0.74

9.95

 

1203

1009

20

0.84

10.05

 

1423

1229

23

0.96

10.17

 

1761

1567

25

1.1

10.31

 

1988

1794

Table 4.2: Plain Concrete + 1 FRP strip reinforced beam (Indoor)

ID 3

Steel + 1FRB

Failed at 25 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

0

0

-13

1

0.08

15

15

2

3

0.16

48

46

33

5

0.22

77

73

60

7

0.28

137

119

106

10

0.41

359

271

258

12

0.5

585

460

447

15

0.61

864

683

670

17

0.71

1138

874

861

20

0.85

1477

1139

1126

22

0.95

1670

1307

1294

25

1.04

1534

1481

1468

20

1.52

1397

1138

1125

14

2.45

1138

926

913

12

3.86

1236

1005

992

Table 4.3: Steel + 1 FRP strip reinforced beam (Indoor)

ID 4

Steel + 2FRB

Failed at 36 kN

 

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

1.24

-2

0

0

-30

1

0.31

1.55

10

12

11

-19

3

0.47

1.71

25

27

43

13

5

0.59

1.83

48

50

67

37

7

0.66

1.9

74

76

106

76

10

0.75

1.99

135

137

222

192

13

0.82

2.06

215

217

298

268

15

0.87

2.11

291

293

413

383

18

0.97

2.21

453

455

585

555

20

1.01

2.25

502

504

663

633

23

1.11

2.35

616

618

788

758

25

1.17

2.41

692

694

883

853

28

1.26

2.5

813

815

1009

979

30

1.32

2.56

883

885

1110

1080

33

1.4

2.64

988

990

1137

1107

36

1.87

3.11

940

942

1211

1181

34

4.15

5.39

530

532

811

781

Table 4.4: Steel + 2 FRP strip reinforced beam (Indoor)

Hot weather with 100% humidity samples (HH):

HH1

Steel

Failed at 11 kN

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

0

0

1.02

0

 

1

0.13

1.15

13

 

2

0.19

1.21

26

 

4

0.26

1.28

64

 

6

0.32

1.34

110

 

8

0.4

1.42

323

 

10

0.68

1.7

 

 

11

4.29

5.31

 

 

12

6.95

7.97

 

 

12

8.53

9.55

 

 

12

10.02

11.04

 

 

Table 4.5: Steel reinforced beam (Hot 100% humidity)

 

HH2

Plain + 1FRB

Failed at 22 kN

 

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

7.91

 

0

8

1

0.06

7.97

 

13

21

3

0.1

8.01

 

40

48

5

0.12

8.03

 

64

72

7

0.16

8.07

 

89

97

10

0.19

8.1

 

165

173

12

0.22

8.13

 

254

262

15

0.39

8.3

 

596

604

17

0.49

8.4

 

801

809

20

0.64

8.55

 

1059

1067

22

0.75

8.66

 

1242

1250

Table 4.6: Plain Concrete + 1 FRP strip reinforced beam (Hot 100% humidity)

HH3

Steel + 1FRB

Failed at 21 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

32

0

0

-2

1

0.04

50

18

19

17

3

0.06

65

33

42

40

5

0.16

108

76

88

86

7

0.21

155

123

138

136

10

0.33

245

213

262

260

12

0.39

310

278

352

350

15

0.5

450

418

572

570

17

0.62

630

598

832

830

20

0.69

718

686

976

974

22

0.79

850

818

1169

1167

25

0.91

980

948

1462

1460

28

1.06

490

458

1774

1772

15

2.47

500

468

992

990

16

3.3

518

486

1006

1004

Table 4.7: Steel + 1 FRP strip reinforced beam (Hot 100% humidity)

HH4

Steel + 2FRB

Failed at 40 kN

 

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

1.41

didn't work

0

-954

1

0.14

1.55

didn't work

6

-948

3

0.24

1.65

didn't work

26

-928

5

0.35

1.76

didn't work

46

-908

7

0.41

1.82

didn't work

71

-883

10

0.48

1.89

didn't work

106

-848

12

0.52

1.93

didn't work

131

-823

15

0.57

1.98

didn't work

178

-776

17

0.61

2.02

didn't work

302

-652

20

0.66

2.07

didn't work

421

-533

22

0.7

2.11

didn't work

520

-434

25

0.77

2.18

didn't work

663

-291

28

0.83

2.24

didn't work

784

-170

30

0.89

2.3

didn't work

876

-78

32

0.93

2.34

didn't work

1032

78

35

1

2.41

didn't work

1081

127

37

1.07

2.48

didn't work

1194

240

40

1.11

2.52

didn't work

1271

317

20

1.29

2.7

didn't work

1434

480

22

1.49

2.97

didn't work

1214

260

Table 4.8: Steel + 2 FRP strip reinforced beam (Hot 100% humidity)

Hot weather with 0% humidity (Furnace samples) (F):

F1

Steel

Failed at 11 kN

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

0

0

didn't work

 

1

0.08

didn't work

 

3

0.19

didn't work

 

5

0.28

didn't work

 

7

0.35

didn't work

 

10

0.75

didn't work

 

11

1.5

didn't work

 

11

3.72

didn't work

 

10

4.06

didn't work

 

10

5.73

didn't work

 

10

6.86

didn't work

 

Table 4.9: Steel reinforced beam (Hot 0% humidity)

F2

Plain + 1FRP

Failed at 20 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

 

0

-176

1

0.05

 

9

-167

3

0.11

 

32

-144

5

0.16

 

59

-117

7

0.21

 

91

-85

10

0.28

 

133

-43

12

0.38

 

629

453

15

0.48

 

751

575

17

0.59

 

1201

1025

20

0.79

 

1130

954

Table 4.10: Plain Concrete + 1 FRP strip reinforced beam (Hot 0% humidity)

F3

Steel + 1FRP

Failed at 21 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

3

0

0

10

1

0.05

22

19

14

24

3

0.11

67

64

52

62

5

0.15

126

123

95

105

7

0.17

215

212

146

156

10

0.25

580

577

299

309

12

0.3

791

788

408

418

17

0.47

1300

1297

862

872

20

0.57

1481

1478

1043

1053

21

1.05

1070

1067

813

823

16

1.69

1202

1199

894

904

12

2.24

1062

1059

820

830

12

3.15

1062

1059

850

860

Table: 4.11: Steel + 1 FRP strip reinforced beam (Hot 0% humidity)

F4

Steel + 2FRP

Failed at 31 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

-3

0

0

15

1

0.06

19

22

16

31

3

0.12

48

51

43

58

5

0.18

85

88

77

92

7

0.25

132

135

117

132

10

0.34

238

241

201

216

12

0.38

289

292

266

281

15

0.47

432

435

398

413

17

0.51

508

511

518

533

20

0.6

631

634

655

670

22

0.65

720

723

742

757

25

0.75

856

859

969

984

27

0.81

952

955

1112

1127

30

0.91

1100

1103

1328

1343

31

1.55

872

875

1374

1389

19

2.36

793

796

1312

1327

Table: 4.12: Steel + 2 FRP strip reinforced beam (Hot 0% humidity)

Outdoor samples (OD):

OD1

Steel

Failed at 11 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

0

0

6

0

 

1

0.06

13

7

 

2

0.11

27

21

 

4

0.26

65

59

 

6

0.36

144

138

 

8

0.45

323

317

 

10

0.78

1585

1579

 

11

2.1

2025

2019

 

10

3.45

1455

1449

 

11

4.5

1180

1174

 

10

5.91

1215

1209

 

9

7.96

878

872

 

9

9.82

1037

1031

 

10

10.3

1332

1326

 

Table 4.13: : Steel reinforced beam (Outdoor)

 

OD2

Plain + 1FRP

Failed at 23 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

 

-2

0

1

0.08

 

377

379

3

0.18

 

400

402

5

0.22

 

423

425

7

0.3

 

456

458

10

0.36

 

506

508

12

0.4

 

565

567

15

0.58

 

837

839

17

0.67

 

1210

1212

20

0.7

 

1525

1527

21

0.76

 

1670

1672

23

0.79

 

1874

1876

Table 4.14: : Plain Concrete + 1 FRP strip reinforced beam (Outdoor)

OD3

Steel + 1FRP

Failed at 27 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

23

0

0

-673

1

0.05

53

30

22

-651

3

0.09

78

55

43

-630

5

0.12

115

92

73

-600

7

0.16

147

124

98

-575

10

0.25

360

337

236

-437

12

0.3

514

491

336

-337

15

0.42

880

857

600

-73

17

0.51

1106

1083

791

118

20

0.63

1352

1329

1023

350

23

0.76

1630

1607

1253

580

25

0.86

1813

1790

1413

740

27

2.55

1450

1427

1111

438

18

4.05

1214

1191

1023

350

Table 4.15: Steel + 1 FRP strip reinforced beam (Outdoor)

OD4

Steel + 2FRP

Failed at 30 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

-2

0

0

2

1

0.06

14

16

11

13

3

0.15

37

39

40

42

5

0.21

73

75

70

72

7

0.25

102

104

96

98

10

0.3

216

218

156

158

12

0.34

302

304

198

200

15

0.39

423

425

266

268

17

0.44

538

540

383

385

20

0.5

670

672

558

560

22

0.54

769

771

652

654

25

0.63

925

927

802

804

27

0.66

960

962

843

845

30

0.73

1085

1087

978

980

31

0.74

780

782

1044

1046

20

1.84

763

765

1068

1070

22

1.85

800

802

1061

1063

24

2.7

806

808

1098

1100

26

2.88

854

856

1165

1167

28

3.05

894

896

1198

1200

Table 4.16: Steel + 2 FRP strip reinforced beam (Outdoor)

 

Load VS Deflection for the four environments:

Figure 4.5: Load VS Deflection for Indoor samples.

Figure 4.6: Load VS Deflection for Hot weather with 100% humidity.

Figure 4.7: Load VS Deflection for Hot weather with 0% humidity.

Figure 4.8: Load VS Deflection for Outdoor samples.

 

 

 

 

 

 

 

Load VS Steel Strain for the four environments:

Figure 4.9: Load VS Steel Strain for Indoor samples.

Figure 4.10: Load VS Steel Strain for Hot weather with 100% humidity.

 

 

Figure 4.11: Load VS Steel Strain for Hot weather with 0% humidity.

Figure 4.12: Load VS Steel Strain for Outdoor samples.

 

 

 

 

 

 

 

Load VS FRP Strain for the four environments:

Figure 4.13: Load VS FRP Strain for Indoor samples.

Figure 4.14: Load VS FRP Strain for Hot weather with 100% humidity.

 

Figure 4.15: Load VS FRP Strain for Hot weather with 0% humidity.

Figure 4.16: Load VS FRP Strain for Outdoor samples.

 

Figure 4.17: Load VS Deflection for steel reinforced beams in all environments.

Figure 4.18: Load VS Deflection for plain concrete + 1 FRP strip reinforced beams in all environments.

 

Figure 4.19: Load VS Deflection for Steel + 1 FRP strip reinforced beams in all environments.

Figure 4.20: Load VS Deflection for Steel + 2 FRP strip reinforced beams in all environments.

 

 

 

Figure 4.21: Load VS Steel Strain for steel reinforced beams in all environments.

Figure 4.22: Load VS Steel Strain for Steel + 1 FRP strip reinforced beams in all environments.

Figure 4.23: Load VS Steel Strain for Steel + 2 FRP strip reinforced beams in all environments.

Figure 4.24: Load VS FRP Strain for plain concrete + 1 FRP strip reinforced beams in all environments.

Figure 4.25: Load VS FRP Strain for Steel  + 1 FRP strip reinforced beams in all environments.

Figure 4.26: Load VS FRP Strain for Steel + 2 FRP strip reinforced beams in all environments.

 

 

 

 

 

Figure 4.27: Fixing FRP strips.

Figure 4.28: FRP and Steel Strain measurement Device.

Figure 4.29: Testing Machine.

 

 

 

Figure 4.30: preparing beam before test.

Figure 4.31: Beam under loading and measuring the deflection.

Figure 4.32: Recording the readings for beams in all environments.

Figure 4.33: Beams before testing.

 

Figure 4.34: Beams after testing.

 

 

Appendix A:

·   Note that all values in shaded cells were the experimental reading before adjustment.

·   All strains readings in tables and figures are in micro strain unit.

Indoor Samples (ID):

ID 1

Steel

Failed at 9 kN

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

0

0

8.04

-15

0

 

1

0.07

8.11

6

21

 

3

1.16

9.2

43

58

 

5

1.24

9.28

103

118

 

9

2.76

10.8

2655

2670

 

10

3.94

11.98

 

 

 

10.5

6.86

14.9

 

 

 

11

9.82

17.86

 

 

 

11

13.66

21.7

 

 

 

10

16.36

24.4

 

 

 

8

17.88

25.92

 

 

 

Table 4.1: Steel reinforced beam (Indoor)

ID 2

Plain + 1FRB

Failed at 26 kN

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

9.21

 

0

-194

1

0.06

9.27

 

12

-182

3

0.15

9.36

 

40

-154

5

0.22

9.43

 

61

-133

7

0.27

9.48

 

84

-110

10

0.35

9.56

 

190

-4

12

0.41

9.62

 

328

134

15

0.56

9.77

 

727

533

18

0.74

9.95

 

1203

1009

20

0.84

10.05

 

1423

1229

23

0.96

10.17

 

1761

1567

25

1.1

10.31

 

1988

1794

Table 4.2: Plain Concrete + 1 FRP strip reinforced beam (Indoor)

ID 3

Steel + 1FRB

Failed at 25 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

0

0

-13

1

0.08

15

15

2

3

0.16

48

46

33

5

0.22

77

73

60

7

0.28

137

119

106

10

0.41

359

271

258

12

0.5

585

460

447

15

0.61

864

683

670

17

0.71

1138

874

861

20

0.85

1477

1139

1126

22

0.95

1670

1307

1294

25

1.04

1534

1481

1468

20

1.52

1397

1138

1125

14

2.45

1138

926

913

12

3.86

1236

1005

992

Table 4.3: Steel + 1 FRP strip reinforced beam (Indoor)

ID 4

Steel + 2FRB

Failed at 36 kN

 

 

 

 

Load (kN)

Deflection mm

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

1.24

-2

0

0

-30

1

0.31

1.55

10

12

11

-19

3

0.47

1.71

25

27

43

13

5

0.59

1.83

48

50

67

37

7

0.66

1.9

74

76

106

76

10

0.75

1.99

135

137

222

192

13

0.82

2.06

215

217

298

268

15

0.87

2.11

291

293

413

383

18

0.97

2.21

453

455

585

555

20

1.01

2.25

502

504

663

633

23

1.11

2.35

616

618

788

758

25

1.17

2.41

692

694

883

853

28

1.26

2.5

813

815

1009

979

30

1.32

2.56

883

885

1110

1080

33

1.4

2.64

988

990

1137

1107

36

1.87

3.11

940

942

1211

1181

34

4.15

5.39

530

532

811

781

Table 4.4: Steel + 2 FRP strip reinforced beam (Indoor)

Hot weather with 100% humidity samples (HH):

HH1

Steel

Failed at 11 kN

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

0

0

1.02

0

 

1

0.13

1.15

13

 

2

0.19

1.21

26

 

4

0.26

1.28

64

 

6

0.32

1.34

110

 

8

0.4

1.42

323

 

10

0.68

1.7

 

 

11

4.29

5.31

 

 

12

6.95

7.97

 

 

12

8.53

9.55

 

 

12

10.02

11.04

 

 

Table 4.5: Steel reinforced beam (Hot 100% humidity)

 

HH2

Plain + 1FRB

Failed at 22 kN

 

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

7.91

 

0

8

1

0.06

7.97

 

13

21

3

0.1

8.01

 

40

48

5

0.12

8.03

 

64

72

7

0.16

8.07

 

89

97

10

0.19

8.1

 

165

173

12

0.22

8.13

 

254

262

15

0.39

8.3

 

596

604

17

0.49

8.4

 

801

809

20

0.64

8.55

 

1059

1067

22

0.75

8.66

 

1242

1250

Table 4.6: Plain Concrete + 1 FRP strip reinforced beam (Hot 100% humidity)

HH3

Steel + 1FRB

Failed at 21 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

32

0

0

-2

1

0.04

50

18

19

17

3

0.06

65

33

42

40

5

0.16

108

76

88

86

7

0.21

155

123

138

136

10

0.33

245

213

262

260

12

0.39

310

278

352

350

15

0.5

450

418

572

570

17

0.62

630

598

832

830

20

0.69

718

686

976

974

22

0.79

850

818

1169

1167

25

0.91

980

948

1462

1460

28

1.06

490

458

1774

1772

15

2.47

500

468

992

990

16

3.3

518

486

1006

1004

Table 4.7: Steel + 1 FRP strip reinforced beam (Hot 100% humidity)

HH4

Steel + 2FRB

Failed at 40 kN

 

 

 

Load (kN)

Deflection (mm)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

1.41

didn't work

0

-954

1

0.14

1.55

didn't work

6

-948

3

0.24

1.65

didn't work

26

-928

5

0.35

1.76

didn't work

46

-908

7

0.41

1.82

didn't work

71

-883

10

0.48

1.89

didn't work

106

-848

12

0.52

1.93

didn't work

131

-823

15

0.57

1.98

didn't work

178

-776

17

0.61

2.02

didn't work

302

-652

20

0.66

2.07

didn't work

421

-533

22

0.7

2.11

didn't work

520

-434

25

0.77

2.18

didn't work

663

-291

28

0.83

2.24

didn't work

784

-170

30

0.89

2.3

didn't work

876

-78

32

0.93

2.34

didn't work

1032

78

35

1

2.41

didn't work

1081

127

37

1.07

2.48

didn't work

1194

240

40

1.11

2.52

didn't work

1271

317

20

1.29

2.7

didn't work

1434

480

22

1.49

2.97

didn't work

1214

260

Table 4.8: Steel + 2 FRP strip reinforced beam (Hot 100% humidity)

Hot weather with 0% humidity (Furnace samples) (F):

F1

Steel

Failed at 11 kN

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

0

0

didn't work

 

1

0.08

didn't work

 

3

0.19

didn't work

 

5

0.28

didn't work

 

7

0.35

didn't work

 

10

0.75

didn't work

 

11

1.5

didn't work

 

11

3.72

didn't work

 

10

4.06

didn't work

 

10

5.73

didn't work

 

10

6.86

didn't work

 

Table 4.9: Steel reinforced beam (Hot 0% humidity)

F2

Plain + 1FRP

Failed at 20 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

 

0

-176

1

0.05

 

9

-167

3

0.11

 

32

-144

5

0.16

 

59

-117

7

0.21

 

91

-85

10

0.28

 

133

-43

12

0.38

 

629

453

15

0.48

 

751

575

17

0.59

 

1201

1025

20

0.79

 

1130

954

Table 4.10: Plain Concrete + 1 FRP strip reinforced beam (Hot 0% humidity)

F3

Steel + 1FRP

Failed at 21 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

3

0

0

10

1

0.05

22

19

14

24

3

0.11

67

64

52

62

5

0.15

126

123

95

105

7

0.17

215

212

146

156

10

0.25

580

577

299

309

12

0.3

791

788

408

418

17

0.47

1300

1297

862

872

20

0.57

1481

1478

1043

1053

21

1.05

1070

1067

813

823

16

1.69

1202

1199

894

904

12

2.24

1062

1059

820

830

12

3.15

1062

1059

850

860

Table: 4.11: Steel + 1 FRP strip reinforced beam (Hot 0% humidity)

F4

Steel + 2FRP

Failed at 31 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

-3

0

0

15

1

0.06

19

22

16

31

3

0.12

48

51

43

58

5

0.18

85

88

77

92

7

0.25

132

135

117

132

10

0.34

238

241

201

216

12

0.38

289

292

266

281

15

0.47

432

435

398

413

17

0.51

508

511

518

533

20

0.6

631

634

655

670

22

0.65

720

723

742

757

25

0.75

856

859

969

984

27

0.81

952

955

1112

1127

30

0.91

1100

1103

1328

1343

31

1.55

872

875

1374

1389

19

2.36

793

796

1312

1327

Table: 4.12: Steel + 2 FRP strip reinforced beam (Hot 0% humidity)

Outdoor samples (OD):

OD1

Steel

Failed at 11 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

0

0

6

0

 

1

0.06

13

7

 

2

0.11

27

21

 

4

0.26

65

59

 

6

0.36

144

138

 

8

0.45

323

317

 

10

0.78

1585

1579

 

11

2.1

2025

2019

 

10

3.45

1455

1449

 

11

4.5

1180

1174

 

10

5.91

1215

1209

 

9

7.96

878

872

 

9

9.82

1037

1031

 

10

10.3

1332

1326

 

Table 4.13: : Steel reinforced beam (Outdoor)

 

OD2

Plain + 1FRP

Failed at 23 kN

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Fiber

Strain Fiber

0

0

 

-2

0

1

0.08

 

377

379

3

0.18

 

400

402

5

0.22

 

423

425

7

0.3

 

456

458

10

0.36

 

506

508

12

0.4

 

565

567

15

0.58

 

837

839

17

0.67

 

1210

1212

20

0.7

 

1525

1527

21

0.76

 

1670

1672

23

0.79

 

1874

1876

Table 4.14: : Plain Concrete + 1 FRP strip reinforced beam (Outdoor)

OD3

Steel + 1FRP

Failed at 27 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

23

0

0

-673

1

0.05

53

30

22

-651

3

0.09

78

55

43

-630

5

0.12

115

92

73

-600

7

0.16

147

124

98

-575

10

0.25

360

337

236

-437

12

0.3

514

491

336

-337

15

0.42

880

857

600

-73

17

0.51

1106

1083

791

118

20

0.63

1352

1329

1023

350

23

0.76

1630

1607

1253

580

25

0.86

1813

1790

1413

740

27

2.55

1450

1427

1111

438

18

4.05

1214

1191

1023

350

Table 4.15: Steel + 1 FRP strip reinforced beam (Outdoor)

OD4

Steel + 2FRP

Failed at 30 kN

 

 

 

Load (kN)

Deflection (mm)

Strain Steel

Strain Steel

Strain Fiber

Strain Fiber

0

0

-2

0

0

2

1

0.06

14

16

11

13

3

0.15

37

39

40

42

5

0.21

73

75

70

72

7

0.25

102

104

96

98

10

0.3

216

218

156

158

12

0.34

302

304

198

200

15

0.39

423

425

266

268

17

0.44

538

540

383

385

20

0.5

670

672

558

560

22

0.54

769

771

652

654

25

0.63

925

927

802

804

27

0.66

960

962

843

845

30

0.73

1085

1087

978

980

31

0.74

780

782

1044

1046

20

1.84

763

765

1068

1070

22

1.85

800

802

1061

1063

24

2.7

806

808

1098

1100

26

2.88

854

856

1165

1167

28

3.05

894

896

1198

1200

Table 4.16: Steel + 2 FRP strip reinforced beam (Outdoor)

 

Load VS Deflection for the four environments:

Figure 4.5: Load VS Deflection for Indoor samples.

Figure 4.6: Load VS Deflection for Hot weather with 100% humidity.

Figure 4.7: Load VS Deflection for Hot weather with 0% humidity.

Figure 4.8: Load VS Deflection for Outdoor samples.

 

 

 

 

 

 

 

Load VS Steel Strain for the four environments:

Figure 4.9: Load VS Steel Strain for Indoor samples.

Figure 4.10: Load VS Steel Strain for Hot weather with 100% humidity.

 

 

Figure 4.11: Load VS Steel Strain for Hot weather with 0% humidity.

Figure 4.12: Load VS Steel Strain for Outdoor samples.

 

 

 

 

 

 

 

Load VS FRP Strain for the four environments:

Figure 4.13: Load VS FRP Strain for Indoor samples.

Figure 4.14: Load VS FRP Strain for Hot weather with 100% humidity.

 

Figure 4.15: Load VS FRP Strain for Hot weather with 0% humidity.

Figure 4.16: Load VS FRP Strain for Outdoor samples.

 

Figure 4.17: Load VS Deflection for steel reinforced beams in all environments.

Figure 4.18: Load VS Deflection for plain concrete + 1 FRP strip reinforced beams in all environments.

 

Figure 4.19: Load VS Deflection for Steel + 1 FRP strip reinforced beams in all environments.

Figure 4.20: Load VS Deflection for Steel + 2 FRP strip reinforced beams in all environments.

 

 

 

Figure 4.21: Load VS Steel Strain for steel reinforced beams in all environments.

Figure 4.22: Load VS Steel Strain for Steel + 1 FRP strip reinforced beams in all environments.

Figure 4.23: Load VS Steel Strain for Steel + 2 FRP strip reinforced beams in all environments.

Figure 4.24: Load VS FRP Strain for plain concrete + 1 FRP strip reinforced beams in all environments.

Figure 4.25: Load VS FRP Strain for Steel  + 1 FRP strip reinforced beams in all environments.

Figure 4.26: Load VS FRP Strain for Steel + 2 FRP strip reinforced beams in all environments.

 

 

 

 

 

Figure 4.27: Fixing FRP strips.

Figure 4.28: FRP and Steel Strain measurement Device.

Figure 4.29: Testing Machine.

 

 

 

Figure 4.30: preparing beam before test.

Figure 4.31: Beam under loading and measuring the deflection.

Figure 4.32: Recording the readings for beams in all environments.

Figure 4.33: Beams before testing.

 

Figure 4.34: Beams after testing.

 

 

 

Home Page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 