Elex HK

StairLift

29/03/2001

STC Dept

COP on the Design & Construction of Lifts & Escalators (1993)

Einstein Y Y Co

Clause

Requirements

Status

1.1

l           Motor & gearbox thermal time ratings shall be not less than 25%

l           Gearbox wear rating (minimum life of 100,000 starts & 2,500 hours at full load)

 

2.2

l           Angle of inclination =< 45°

 

2.3

l           Clear height above platform => 2m

 

3

l           General safety factor of all parts >=3

 

4

l           Rail safety factor=>5 (base on rated load)

 

5.1

5.2

l           Rated speed <= 0.15 m/s

l           Rated load of chair carriage >= 115 kg

l           Rated load for power-driven wheelchair >= 225 kg

l           Rated load for manual wheelchair >= 205 kg (platform area > 0.84 sq.m.)

l           Rated load for manual wheelchair >= 150 kg (platform area <= 0.84 sq.m.)

 

6.2.2

l           Geared drive unit safety factor=> 6

 

6.2.3

l           Braking distance =< 20mm (applied mechanically & held off electrically)

 

6.3.1

l           Rope safety factor => 12

 

7

l           Carriage (a) chair carriage, (b) standing platform, (c) wheelchair platform

 

7.1

l           Carriage safety factor => 5 (base on the rated load)

 

7.1.2

l           Load plated shall be mounted on the carriage or at each landing

l           (At least 10mm height of letters)

 

7.1.3

l           Nameplate shall be provided on the carriage

 

7.2.1

l           Safety gear operating in downward direction only

l           Release of the safety gear by raising the carriage up the rail

 

7.2.2

l           Overspeed governor actuated at least 115% of rated speed but =<0.3 m/s

 

 

l            

 

9.6

l           Final limit safety switches shall be provided at each end of travel

 

 

l            

 

11.1

l           (Self-operation) Common key shall be provided at each landing & removable only from the “off” position

 

12.1

l            

 

12.3

l           (Attendant-operated stairlift) No controls, other than a stopping device, shall be provided on the carriage

 

 

l            

 

13.1

l           User guide in both English & Chinese shall be affixed to the stairlift

 

13.2

l           Operation manual laminated with plastic protective sheets shall be kept in management office

 

 

l            

 

 

l            

 

 

l            

 

 

l            

 

 

Hosted by www.Geocities.ws