The Department of Agriculture, Regional Field Unit No. 6 Iloilo City invites all accredited suppliers/manufacturers /distributors to participate  in the Renegotiation for the Procurement of  87 units Mechanical Flatbed Dryers  with the following description-

 

                        Fabrication, installation and commissioning of the 6 ton BPRE

                        Modified Drying system including supply of BPRE designed

                        Moisture Meter

 

                        Specifications:

The BPRE Modified Flatbed Drying system consists of a Grain Moisture Meter and Flat Bed Dryer consisting of a drying bin made of reinforced concrete panels and bolted construction with perforated metal bed flooring; a blower driven by a diesel engine and a direct-fired biomass fed furnace that serves as the heater.  The dryer is installed with concrete flooring and built-in shed of all metal/steel construction with corrugated GI roofing.

 

                        Drying Bin

·                     made of concrete that can withstand 3,000 psi

·                     panelized concrete walling with metal connection of 3mm thick

·                     knockdown construction

·                     concrete made of class “A” mixture using Portland cement with rebars of not less than 8mm diameter spaced as per drawn

·                     minimum panel thickness of 38.1mm with metal molding/framing on all edges with engraved prescribed label and logo as per drawn

·                     inside dimension of drying bin; width=12.0 ft.,length=24 ft.

·                     total bin height of 1500 mm

·                     height of plenum – 1040mm

·                     grain holding depth of 460 mm with gauge 18 or its equivalent (standard) metal perforated floor having 2.38 mm diameter perforation (about 3/32 inc), complete with bagging ports

·                     adequately supported with frames and braces to withstand a 6 – tons of grain load

·                     equipped with heavy duty dial and probe type thermometer range: 0-100C, probe length not less than 4”

·                     concrete flooring dimension (Class C mixture). L=12m, W=6m, T=3, reinforced with 10mm diameter deformed bar spaced at 1m along length and breadth

·                     one of the panels should have handle

 

Furnace

 

·                     total knockdown panelized construction framed by heavy gauge metal/steel materials

·                     panel made of materials with appropriate insulating  and refractory properties that can withstand heat not less than 8000C (fire bricks)- should also be covered by a warranty

·                     panel thickness not less than 38.1 mm, properly reinforced

·                     step grate furnace design with inclination of 45 degrees from the horizontal with grate area of 530 mm x 840 mm

·                     step grate furnace element made of MS flat bar with min. width of 2 inches (50.2 mm) and thickness of ¼ inch (6.35 mm) spaced 11.0mm on center

·                     complete with feeding hopper with shutter valve made of 3mm MS plate

·                     provided with 2 mid baffles/panels spaced 8” on centers with area opening adequate for flue gas exit

 

                       Shed

 

·                     with 8 GI pipe post having 1.2 meters height mounted on top of the bin panel

·                     all bolted construction

·                     truss/rafflers, and purlins made of metal sheet with 1.2 mm thickness

·                     GI sheet roofing of GA# 26 (standard) properly secured with standard GI roofing tie wire (galvanized iron)

 

                  Blower and Engine

 

·                     axial blower with airflow capacity of 10,500 cfm at 30 mm water static pressure

·                     driven by 12.0 hp diesel engine made of Japanese based Technology , water cooled,single cylinder type, manual/hand cracked starting

·                     diameter of blower housing = 30 inches (762 mm) of GI sheet metal construction of GA #16 (standard)

·                     length of housing = 25 inches (635 mm)

·                     dynamically balanced with appropriate bearings and shafting

·                     with built-in engine mounting

·                     Blower and Engine are AMTEC Tested and meet minimum performance specifications

 

                        Moisture Meter

Preferably BPRE Moisture Meter or of known brand with the following specification:

 

·                     Capacitance type

·                     Digital Output

·                     For Palay and Corn

·                     Measurement range:

Palay: 9-36% MCwb

Corn : 9-36% MCwb

·                     Resolution 0.1% MCwb

·                     Accuracy       0.5% MCwb

·                     Repeatability 99%

·                     AMTEC tested and meet minimum performance specification

 

Warranty: For fabricated parts such as bin and shed, furnace, blower

-          3 years or 86,400 bags of palay dried whichever comes first

For engine based on manufacturer’s warranty but not less than 1 year and unlimited free calibration service

 

Project sites : Regionwide

             

Other interested suppliers/manufacturers/distributors must submit requirements for accreditation in order to participate in the negotiation for said procurement.

 

Deadline for submission of documents for accreditation and offer is on or before  5:00 P.M.  (August 13, 2009) .

 

 

REQUIREMENTS  FOR ACCREDITATION

 

 

  1. Company  Profile
  2. DTI  Registration (Sole Proprietorship )

SEC Registration (Corporation)

  1. License to Operate (Mayor’s Permit)
  2. ITR for the last  two years (stamped received by BIR)
  3. Audited Financial Statement for the last two years
  4. VAT/E-VAT/NON-VAT Registration
  5. Number of Employees/Organizational Chart (certified by HRD Manager)
  6. List of Clients with their respective telephone number and addresses
  7. The company must indicate in its application the category/classification/grouping they would like to participate in (AMDA)
  8. Certification that the Company is not affiliated with other companies with similar nature
  9. Listing of products/services offered.
  10. Certification of dealership from authorized distributor
  11. Certificate of Sole Distributorship ( in case of being an exclusive distributor)
  12. Technical Specifications (brochures)
  13. AMTEC Test for blower, engine and moisture meter
  14. Sworn Statement that each of the documents submitted is an original or true and faithful copy of the original or must be duly notarized.

 

 Note : Items Nos. 9,12, and 13  are optional requirements

 

 

                                                                              LARRY P. NACIONALES

                                                                              OIC-Regional Executive Director

                                                                         

 

 

 

 

Hosted by www.Geocities.ws

1