When the DGN of SS is going on, one SSC goes to suspect and the job aborted.

 

  • This is a quite regular problem of CM in case of SS diagnosis.
  • The DGN of SS aborted and momentarily the standby SSC goes to SUS.
  • The DGN of SSC performed by Standby SSC, and if the link (i.e. Processor Hardware) and SSBID/CBX is faulty the SS DGN is not possible.
  • This is purely a hardware problem and this can be eliminated by interchanging the SSC and verify whether the result is same for a particular SS.
  • If the DGN passes with one SSC and aborted with another SSC then the problem is with SSC card, otherwise the problem exist in SS hardware i.e. CBX or SSBID. Verify the same and repeat the DGN.

 

 