CM Code/Data Loading Problem
NOTE:
Please use the BP cable according to your Hardware i.e MAX-L (ACB-RSUVTEZX-00)
, Baud Rate 4800 , Connection Position 42A1, MAX-XL(ACB-MAXXBPTX-000)
, Baud Rate 9600 , Connection Position 6-J20/J36-1 (FOR FURTHER DETAILS
REFER BP TERMINAL DOC )
•No Prompt on the BP monitor
Check the correct position of source connector of BP cable.
Change the 25 pin connector side from VDU.
Check the proper checksum of SSC card with respect to the s/w rel.
Check the Hardware and jumper setting of the CPU/BPC card used as
SSC.
Check all the four PSUs of SCU and confirm that all the LEDs are glowing.
Jumper Setting of Proc. Card
Pin Nos. 2 & 3 of W19, W20 are to be shorted
Pin Nos. 1 & 2 of W21 are to be shorted for SCU
Pin Nos. 1 & 2 of W22 to W29 are to be shorted for SCU