Home
Helpline
|
|
One
SS goes to ‘sus’ and the other one goes to ‘frc’.
- One SS goes to ‘sus’ and
the other one goes to ‘frc’.
- This type of status happen sometimes in CM-XL and this is
purely due to the fault in clock card i.e. NSC.
- This type of situation generally arise when both the NSC goes
faulty due to the mismatch in clock, causing one copy to suspect and
another to In service Force (INS-FRC).
- If this situation arises then first go for the DGN of Suspect
unit, after making it to OOS-OPR. Once the DGN of that SS pass put the
same to INS.
- As soon as the same becomes INS-ACT the INS-FRC unit goes
to SUS. Make the same to OOS-OPR and do the DGN to check whether its
hardware is perfect or not.
|
|
|