One SS goes to ‘sus’ and the other one goes to ‘frc’.

  • One SS goes to ‘sus’ and the other one goes to ‘frc’.
  • This type of status happen sometimes in CM-XL and this is purely due to the fault in clock card i.e. NSC.
  • This type of situation generally arise when both the NSC goes faulty due to the mismatch in clock, causing one copy to suspect and another to In service Force (INS-FRC).
  • If this situation arises then first go for the DGN of Suspect unit, after making it to OOS-OPR. Once the DGN of that SS pass put the same to INS.
  • As soon as the same becomes INS-ACT the INS-FRC unit goes to SUS. Make the same to OOS-OPR and do the DGN to check whether its hardware is perfect or not.
 

 