Code/Data Loading Problem
NOTE:
Pl. use the BP cable according to your Hardware i.e MAX-L
(ACB-RSUVTEZX-00) , Baud Rate 4800 , Connection Position 42A1 MAX-XL(ACB-MAXXBPTX-000)
, Baud Rate 9600 , Connection Position 6-J20/J36-1 (FOR FURTHER DETAILS
REFER BP TERMINAL DOC )
•NO prompt / Power
ON test not occurring.
Check the correct position of source connector
of BP cable.
Change the 25 pin connector side from VDU.
Check the proper checksum of APC card with respect to the s/w rel.
Check the Hardware and jumper setting of the CPU/BPC card used as
APC.
Check all the four PSUs of APU and confirm that all the LEDs are glowing.
Jumper
Setting of Proc. Card
Pin Nos. 2 & 3 of W19, W20 are to be shorted
Pin Nos. 1 & 2 of W21 are to be shorted for APU
Pin Nos. 1 & 2 of W22 to W29 are to be shorted for APU