To use the following calculations, you will
need to know the following:
Vas = equivalent air compliance for the
driver (litres)
Fs = driver resonance frequency
Qts = driver Q at Fs
The following equations will allow you to design a 4th order bandpass system with a desired low frequency limit or a desired gain. You will need to choose a value for "S" that suits your requirements. 4th order bandpass systems where S is less than 0.7 will have a degraded transient response, but wider bandwidth and smaller box requirements. if S = 0.7, then b = 0.7206, passband ripple = 0.00 dB if S = 0.6, then b = 0.9560, passband ripple = 0.35 dB if S = 0.5, then b = 1.2712, passband ripple = 1.25 dB 4th order bandpass system with desired low frequency
limit then, Fl' = (Fl*Qts)/Fs Fh = (Fl'+b)*Fs/Qts Qbp = (Fl'*(Fl'+b))^0.5 Fb = Qbp*Fs/Qts Vf = (2*S*Qts)^2*Vas Vr = Vas/((Qbp/Qts)^2-1) Pa = -40*LOG(1/(Qbp*2*S)) where, Fh = upper -3dB cutoff frequency (Hz)
Qbp = Qtc of sealed chamber
Fb = resonance frequency
of vented chamber(Hz)
Vf = net volume of vented chamber (litres)
Vr = net volume of sealed chamber (litres)
Pa = gain (dB)
4th order bandpass system with desired gain then, Qbp = ((10^(-Pa/40))*2*S)^-1 Fl = ((-b+(b^2+4*Qbp^2)^0.5)/2)*(Fs/Qts) Fh = Fl+(b*Fs/Qts) Fb = Qbp*Fs/Qts Vf = (2*S*Qts)^2*Vas Vr = Vas/((Qbp/Qts)^2-1) where, Fl = lower -3dB cutoff frequency (Hz)
Fh = upper -3dB cutoff frequency (Hz)
Qbp = Qtc of sealed chamber
Fb = tuning frequency of
vented chamber (Hz)
Vf = net volume of vented chamber (litres)
Vr = net volume of sealed chamber (litres)
Pa = gain (dB)
|